Effect of Process Variables on the Holding Time in an Ultrahigh-Temperature Steam Injection System
Authors:
Open Access
- 1 October 1970
- journal article
- Published by American Dairy Science Association in Journal of Dairy Science
- Vol. 53 (10) , 1353-1357
Abstract
Holding time was measured by monitoring' the conductivity of a salt charge at each end of a holding tube on a strip chart recorder. The effect of pressure and temperature of the heated product on the holding time was studied in 88.7-and 113.7-cm tubes. Holding tube pressure was designated as that pressure in excess of the saturated vapor pressure of water at the holding temperature. Excess pressures of about 1 kg/em 2 were required to ensure reproducible measurement of holding time. At excess pressures below 0.7 kg/cm 2 twophase flow existed. Holding time decreased with pressure until all vapor was condensed. Holding time also decreased as temperature increased because of condensate added to the product and because of the reduced density at higher temperatures. A method for predicting holding tube length for a desired holding time or a holding time for a given holding tube length is presented. The prediction, computed from process and system parameters, ensures a safe process from a public health viewpoint. Calculation is based upon heat and mass balances and velocity distribution in a pipeline.Keywords
This publication has 3 references indexed in Scilit:
- Steam Injection HeatingIndustrial & Engineering Chemistry, 1960
- The dispersion of matter in turbulent flow through a pipeProceedings of the Royal Society of London. A. Mathematical and Physical Sciences, 1954
- THE EFFICIENCY OF HOLDING TUBES USED IN HIGH-TEMPERATURE SHORT-TIME PASTEURIZERSJournal of Milk and Food Technology, 1952