Conjunctival Lymphoma in a Child
Authors:
- Michael WaisbourdMWMichael Waisbourd
- Igal LeibovitchILIgal Leibovitch
- Dror SayarDSDror Sayar
- Ronit ElhasidRERonit Elhasid
- 1 May 2011
- journal article
- case report
- Published by Wolters Kluwer Health in Cornea
- Vol. 30 (5) , 598-599
Abstract
Purpose: To evaluate the quality of stromal bed and the safety on endothelium in preparation of donor tissue for Descemet stripping automated endothelial keratoplasty in a masked fashion using 2 mechanical microkeratomes and a femtosecond laser. Methods: Deep anterior lamellar dissection was performed on 15 donor corneas. Central endothelial cell density was calculated using specular microscopy before and after the dissection. One cornea from each of 5 donor pairs was cut with the Moria ALTK system with the CBm microkeratome using the 300-μm head and the mate cut with the Horizon disposable 300-μm microkeratome. Five additional donor corneas were cut with the Intralase 60-kHz FS laser. The donor corneas were then bisected with half of the cornea used for Live/Dead assay to study central endothelial viability. The other halves were sent for scanning electron microscopy of the stromal bed. Qualitative surface roughness of the scanning electron microscopy images was graded by 2 masked observers, and quantitative surface roughness was assessed using roughness evaluation software. Results: The Horizon group showed a smoother stromal bed compared with the Moria or Intralase groups by 2 masked observers. However, the Moria group had the smoothest quantitative score of all the groups when assessed by roughness evaluation software. There was no statistically significant difference among the 3 groups in the percentage change in the central endothelial cell density or percentage of viable central endothelium by Live/Dead assay after the dissection. Conclusions: Both mechanical microkeratomes created smoother stromal bed dissections than the femtosecond laser. All systems provided good endothelial cell viability.Keywords
This publication has 26 references indexed in Scilit:
- In Vivo Laser Confocal Microscopy After Descemet Stripping with Automated Endothelial KeratoplastyAmerican Journal of Ophthalmology, 2008
- Conjunctival tumors in childrenCurrent Opinion in Ophthalmology, 2007
- Histology of Dislocations in Endothelial Keratoplasty (DSEK and DLEK)Cornea, 2006
- Descemet-Stripping Automated Endothelial KeratoplastyCornea, 2006
- Stability of vision, topography, and endothelial cell density from 1 year to 2 years after deep lamellar endothelial keratoplasty surgeryOphthalmology, 2005
- Interferon treatment of childhood conjunctival lymphomaBritish Journal of Ophthalmology, 2003
- Replacing the endothelium without corneal surface incisions or suturesOphthalmology, 2003
- The Societe Francaise d'Oncologie Pediatrique LMB89 protocol: highly effective multiagent chemotherapy tailored to the tumor burden and initial response in 561 unselected children with B-cell lymphomas and L3 leukemiaBlood, 2001
- Conjunctival lymphoid tumorsOphthalmology, 2001
- Conjunctival lymphoma masquerading as chronic conjunctivitisOphthalmology, 1999