Three‐dimensional implant position and orientation after total knee replacement performed with patient‐specific instrumentation systems
Open Access
- 30 October 2013
- journal article
- research article
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 32 (2) , 331-337
Abstract
Patient‐specific instrumentation systems are entering into clinical practice in total knee replacement, but validation tests have yet to determine the accuracy of replicating computer‐based plans during surgery. We performed a fluoroscopic analysis to assess the final implant location with respect to the corresponding preoperative plan. Forty‐four patients were analyzed after using a patient‐specific system based on CT and MRI. Computer aided design implant models and models of the femur and tibia bone portions, as for the preoperative plans, were provided by the manufacturers. Two orthogonal fluoroscopic images of each knee were taken after surgery for pseudo‐biplane imaging; 3D component locations with respect to the corresponding bones were estimated by a shape‐matching technique. Assuming that the corresponding values at the preoperative plan were equal to zero, discrepancies were taken as an indication of accuracy for the systems. A repeatability test revealed that the technique was reliable within 1 mm and 1°. The maximum discrepancies for all the patients for the femoral component were 5.9 mm in a proximo‐distal direction and 4.2° in flexion. Good matching was found between final implantations and preoperative plans with mean discrepancies smaller than 3.1 mm and 1.9°. © 2013 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 32:331–337, 2014.Keywords
This publication has 31 references indexed in Scilit:
- A comparison of radiological and computer navigation measurements of lower limb coronal alignment before and after total knee replacementThe Journal of Bone and Joint Surgery. British volume, 2012
- Preliminary experience with the patient-specific templating total knee arthroplastyActa Orthopaedica, 2012
- Accuracy of Dynamic Tactile-Guided Unicompartmental Knee ArthroplastyThe Journal of Arthroplasty, 2012
- Do Patient-specific Guides Improve Coronal Alignment in Total Knee Arthroplasty?Clinical Orthopaedics and Related Research, 2012
- Improved Accuracy of Alignment With Patient-specific Positioning Guides Compared With Manual Instrumentation in TKAClinical Orthopaedics and Related Research, 2012
- Neutral Mechanical Alignment: A Requirement for Successful TKA: AffirmsOrthopedics, 2011
- In Vivo Normal Knee Kinematics: Is Ethnicity or Gender an Influencing Factor?Clinical Orthopaedics and Related Research, 2011
- Initial experience with custom-fit total knee replacement: intra-operative events and long-leg coronal alignmentInternational Orthopaedics, 2008
- Radiographic and Navigation Measurements of TKA Limb Alignment Do Not CorrelateClinical Orthopaedics and Related Research, 2008
- Alignments and Clinical Results in Conventional and Navigated Total Knee ArthroplastyClinical Orthopaedics and Related Research, 2007