Procedural efficiency, diagnostic yield, and safety of a novel positioning grid combined with a non-coplanar puncture-angle guide for CT-guided percutaneous transthoracic lung biopsy: a retrospective contemporaneous-control study
Open Access
- 1 September 2026
- journal article
- Published by AME Publishing Company in Journal of Thoracic Disease
- Vol. 18 (9) , 1037
Abstract
Background: Computed tomography (CT)-guided percutaneous transthoracic lung biopsy is an important method for obtaining pathological diagnoses of pulmonary lesions. However, conventional manual localization and needle advancement are operator dependent, and technically difficult lesions may require repeated angle adjustments and CT acquisitions. The aim of this study was to evaluate the procedural efficiency, diagnostic performance, and safety of a novel positioning grid combined with a non-coplanar puncture-angle guide. Methods: This single-center, retrospective, nonrandomized contemporaneous-control study included 287 patients who underwent CT-guided percutaneous transthoracic lung biopsy between August 2023 and November 2024. The device group comprised 146 patients treated using the novel positioning grid and angle guide, whereas 141 controls underwent biopsy using a conventional positioning grid without the angle guide. Procedure time, number of CT acquisitions, diagnostic yield, and complications were compared. Multivariable binary logistic regression was used to identify factors associated with pneumothorax. Results: Procedure time was shorter in the device group than in the control group (7.47±2.69 vs. 24.87±7.70 min, Pvs. 6.05±1.99, Pvs. 94.33% (P=0.057). Pneumothorax and hemoptysis were less frequent in the device group (7.53% vs. 26.95% and 1.37% vs. 16.31%, respectively; both Pvs. 33.33%, P=0.52). In multivariable analysis, device-group membership was independently associated with lower odds of pneumothorax [adjusted odds ratio (aOR) =0.19; 95% confidence interval (CI): 0.09–0.40; PConclusions: Use of the novel positioning grid combined with a non-coplanar puncture-angle guide was associated with shorter procedure time, fewer CT acquisitions, and lower rates of pneumothorax and hemoptysis while maintaining a high diagnostic yield. Prospective multi-operator studies are warranted because the present study was nonrandomized and the groups were treated by different operators.Keywords
This publication has 27 references indexed in Scilit:
- Impact of quantitative pulmonary emphysema score on the rate of pneumothorax and chest tube insertion in CT-guided lung biopsiesScientific Reports, 2020
- Risk factors associated with pulmonary hemorrhage and hemoptysis following percutaneous CT-guided transthoracic lung core needle biopsy: a retrospective study of 1,090 casesQuantitative Imaging in Medicine and Surgery, 2020
- Pneumothorax rates in CT-Guided lung biopsies: a comprehensive systematic review and meta-analysis of risk factorsBritish Journal of Radiology, 2020
- Computed tomography–guided lung biopsy: a randomized controlled trial of low-dose versus standard-dose protocolEuropean Radiology, 2019
- Feasibility and accuracy of CT-guided percutaneous needle biopsy of cavitary pulmonary lesionsDiagnostic and Interventional Radiology, 2019
- CT-guided Lung Biopsy: Effect of Biopsy-side Down Position on Pneumothorax and Chest Tube PlacementRadiology, 2019
- Non-Diagnostic CT-Guided Percutaneous Needle Biopsy of the Lung: Predictive Factors and Final DiagnosesKorean Journal of Radiology, 2019
- CT-guided transthoracic core needle biopsy for small pulmonary lesions: diagnostic performance and adequacy for molecular testingJournal of Thoracic Disease, 2017
- Complication rates of CT-guided transthoracic lung biopsy: meta-analysisEuropean Radiology, 2016
- Frequency and Severity of Pulmonary Hemorrhage in Patients Undergoing Percutaneous CT-guided Transthoracic Lung Biopsy: Single-Institution Experience of 1175 CasesRadiology, 2016