A slotted plate device for measuring static yield stress
Authors:
- 1 September 2001
- journal article
- Published by Society of Rheology in Journal of Rheology
- Vol. 45 (5) , 1105-1122
Abstract
A slotted-plate device was constructed with a balance and a linear-motion platform to directly measure static yield stresses of suspensions by moving the plate in the suspension in a similar mode as is done in the well-known Wilhelmy-plate technique for measuringsurface tension. Wall effects associated with the original plate yield-stress instrument [De Kee et al. (1980)] were minimized by opening a series of slots on the plates. Yield-stress experiments were conducted on both high-concentration (40, 50, 60, and 70 wt % TiO 2 ) and low-concentration (2, 3, and 5 wt % bentonite) aqueous suspensions. The new setup avoids the disadvantages of the vane instrument, possible secondary flow between the blades as well as a nonuniform stress distribution along a virtual cylindrical surface. Yield stress values of TiO 2 suspensions were compared with the values obtained via a variety of other methods, including indirect extrapolation from steady-shear data, vane creeptesting, and vane stress-ramp measurements using an SR-5000 rheometer. Very small yield stress (up to ∼10 −4 Pa) measurements of low-concentration bentonite suspensions (2, 3, and 5 wt %) could be determined only with the slotted-plate device. The vane method could not measureyield stress values of bentonite suspensions of less than 7 wt % concentration. Relaxation tests on high-concentration suspensions indicated that these suspensions may not be purely elastic below yield stress.Keywords
This publication has 39 references indexed in Scilit:
- The yield stress—a review or ‘παντα ρει’—everything flows?Journal of Non-Newtonian Fluid Mechanics, 1999
- Thixotropy—a reviewJournal of Non-Newtonian Fluid Mechanics, 1997
- A procedure to determine the material constants and the viscosity function for a fluid with yield shear stressActa Mechanica, 1995
- A review of the slip (wall depletion) of polymer solutions, emulsions and particle suspensions in viscometers: its cause, character, and cureJournal of Non-Newtonian Fluid Mechanics, 1995
- Vane rheometry of bentonite gelsJournal of Non-Newtonian Fluid Mechanics, 1991
- The vane‐in‐cup as a novel rheometer geometry for shear thinning and thixotropic materialsJournal of Rheology, 1990
- Letter to the Editor: The engineering reality of the yield stressJournal of Rheology, 1990
- Yield stress: A time-dependent property and how to measure itRheologica Acta, 1986
- The yield stress myth?Rheologica Acta, 1985
- The Rheology and Flow of Viscoplastic MaterialsReviews in Chemical Engineering, 1983