Influence of Front-Side Ag Metallization on High Temperature and High Humidity Test of Crystalline Silicon PV Module
Authors:
- 1 June 2019
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1525-1528
Abstract
Regarding the crystalline Silicon Photovoltaic module in which the corrosion of the front-side metallization occurred form near the bus bars in the high temperature high humidity test, the state of the finger metallization after the test was observed. Corrosion of the glass of the metallization was confirmed as in the previous report. In addition, there was a gap between the bulk Ag and the glass layer. This gap can cause an increase in series resistance between the emitter and the finger bars. Sn was also detected from a part of the corroded metallization surface.Keywords
This publication has 4 references indexed in Scilit:
- Effect of soldering on the module degradation along bus bar in DH test and PCT for crystalline Si PV modules2018
- PV Module Durability -connecting field results, accelerated testing, and materials2017
- Investigation of Acetic Acid Corrosion Impact on Printed Solar Cell ContactsIEEE Journal of Photovoltaics, 2015
- Origin of damp-heat induced cell degradationSolar Energy Materials and Solar Cells, 2013