Assessment of Global Left Ventricular Function
Authors:
- Walter HundtWHWalter Hundt
- Karen SiebertKSKaren Siebert
- Bernd J WinterspergerBWBernd J Wintersperger
- Christoph R BeckerCBChristoph R Becker
- Andreas KnezAKAndreas Knez
- Maximilian F ReiserMRMaximilian F Reiser
- Geoffrey D RubinGRGeoffrey D Rubin
- 1 May 2005
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Computer Assisted Tomography
- Vol. 29 (3) , 373-381
Abstract
Evaluation of left ventricular function using electrocardiogram (ECG)-gated multidetector row CT (MDCT) by using 3 different volumetric assessment methods in comparison to assessment of the left ventricular function by invasive ventriculography. Thirty patients with suspected or known coronary artery disease underwent MDCT coronary angiography with retrospective ECG cardiac gating. Raw data were reconstructed at the end-diastolic and end-systolic periods of the heart cycle. To calculate the volumes of the left ventricle, 3 methods were applied: The 3-dimensional data set (3D), the geometric hemisphere cylinder (HC), and the geometric biplane ellipsoid (BE) methods. End-diastolic volumes (EDV), end-systolic volumes (ESV), the stroke volumes (SV), and ejection fractions (EF) were calculated. The left ventricular volumetric data from the 3 methods were compared with measurements from left ventriculography (LVG). The best results were obtained using the 3D method; EDV (r = 0.73), ESV (r = 0.88), and EF (r = 0.76) correlated well with the LVG data. The EDV volumes did not differ significantly between LVG and the 3D method (P = 0.24); however, ESV, SV, and EF differed significantly. The ESV were significantly overestimated (P < 0.01), leading to an underestimation of the SV (P < 0.01) and the EF (P < 0.01). The HC method resulted in the greatest overestimation of the volumes. The EDV and the ESV were 31.8 +/- 37.6% and 136.4 +/- 92.9% higher than the EDV and ESV volumes obtained by LVG. Bland-Altman analysis showed systematic overestimation of the ESV using the HC method. MDCT with retrospective cardiac ECG gating allows the calculation of left ventricular volumes to estimate systolic function. The 3D method had the highest correlation with LVG. However, the overestimation of the ESV is significant, which led to an underestimation of the SV and the EF.Keywords
This publication has 45 references indexed in Scilit:
- Detection of Coronary Artery Stenoses With Multislice Helical CT AngiographyJournal of Computer Assisted Tomography, 2002
- Coronary Artery Calcium MeasurementAmerican Journal of Roentgenology, 2001
- Using Intranasal Midazolam Spray to Prevent Claustrophobia Induced by MR ImagingAmerican Journal of Roentgenology, 2001
- Cardiac Imaging by Means of Electrocardiographically Gated Multisection Spiral CT: Initial ExperienceRadiology, 2000
- Imaging of Noncalcified Coronary Plaques Using Helical CT with Retrospective ECG GatingAmerican Journal of Roentgenology, 2000
- Noninvasive Detection of Coronary Artery Stenosis by Multislice Helical Computed TomographyCirculation, 2000
- The Cardiac Insufficiency Bisoprolol Study II (CIBIS-II): a randomised trialThe Lancet, 1999
- Electrocardiogram‐correlated image reconstruction from subsecond spiral computed tomography scans of the heartMedical Physics, 1998
- Increased left ventricular mass and hypertrophy are associated with increased risk for sudden deathJACC, 1998
- Normal left ventricular dimensions and function: interstudy reproducibility of measurements with cine MR imaging.Radiology, 1990