Treatment of inadvertent subclavian artery cannulation with a percutaneous vascular closure device
Authors:
Open Access
- 23 October 2019
- journal article
- Published by KEAI Publishing in Journal of Interventional Medicine
- Vol. 2 (4) , 164-165
Abstract
Inadvertent puncture of the subclavian artery is an uncommon but potentially fatal complication of the commonly performed internal jugular vein catheterization. We report a case of accidental subclavian artery catheterization close to the vertebral artery during internal jugular venous cannulation, which was successfully managed in the interventional suite with catheter removal and use of a vascular closure device.Keywords
This publication has 2 references indexed in Scilit:
- Iatrogenic Percutaneous Vascular Injuries: Clinical Presentation, Imaging, and ManagementSeminars in Interventional Radiology, 2015