Local Myoelectric Sensing During Human Colonic Tissue Perfusion
Open Access
- 20 December 2024
- journal article
- research article
- Published by MDPI AG in Diagnostics
- Vol. 14 (24) , 2870
Abstract
Objectives: Anastomotic leakage (AL) is one of the most devastating complications after colorectal surgery. The verification of the adequate perfusion of the anastomosis is essential to ensuring anastomosis integrity following colonic resections. This study aimed to evaluate the efficacy of measuring the electrical activity of the colonic muscularis externa at an anastomosis site for perfusion analysis following colorectal surgery. Methods: Strips of human isolated colon were maintained in a horizontal tissue bath to record spontaneous contractions and myoelectric activity and spike potentials (using a bipolar electrode array for the wireless transmission of myoelectric data—the xBar system) from the circular muscle. Intraoperative myoelectric signal assessment was performed by placing the electrode array on the colon prior to and following mesenteric artery ligation, just prior to colonic resection. Results: In human isolated colon, the amplitude, duration, and frequency of contractions were inhibited during hypoxia by >80% for each measurement, compared to control values and time-matched oxygenated muscle. Intraoperative (N = 5; mean age, 64.8 years; range, 54–74 years; 60% females) myoelectric signal assessment revealed a decline in spike rate following arterial ligation, with a mean reduction of 112.64 to 51.13 spikes/min (p < 0.0008). No adverse events were observed during the study, and the device did not substantially alter the surgical procedure. Conclusions: The electrical and contraction force of the human colon was reduced by ischemia, both in vitro and in vivo. These preliminary findings also suggest the potential of the xBar system to measure such changes during intraoperative and possibly postoperative periods to predict the risk of anastomotic viability as a surrogate of evolving dehiscence.Keywords
Funding Information
- Exero Medical Ltd.
This publication has 53 references indexed in Scilit:
- Stretchable Device for Simultaneous Measurements of Contractility and Electrophysiology of Neuromuscular Tissue in the Gastrointestinal TractAdvanced Materials, 2024
- Impact of change in the surgical plan based on indocyanine green fluorescence angiography on the rates of colorectal anastomotic leak: a systematic review and meta-analysisSurgical Endoscopy, 2022
- Indocyanine green fluorescent imaging on anastomotic leakage in colectomies: a network meta-analysis and systematic reviewInternational Journal of Colorectal Disease, 2020
- Techniques for intraoperative evaluation of bowel viability in mesenteric ischemia: A reviewThe American Journal of Surgery, 2020
- Intraoperative use of ICG fluorescence imaging to reduce the risk of anastomotic leakage in colorectal surgery: a systematic review and meta-analysisTechniques in Coloproctology, 2017
- Automated Algorithm for GI Spike Burst Detection and Demonstration of Efficacy in Ischemic Small IntestineAnnals of Biomedical Engineering, 2013
- Surgeons lack predictive accuracy for anastomotic leakage in gastrointestinal surgeryInternational Journal of Colorectal Disease, 2009
- Incidence, consequences, and risk factors for anastomotic dehiscence after colorectal surgery: a prospective monocentric studyInternational Journal of Colorectal Disease, 2007
- Altered microperfusion at the rectal stump is predictive for rectal anastomotic leakDiseases of the Colon & Rectum, 2000
- Morphine effects on human colonic myoelectric activity in the postoperative periodThe American Journal of Surgery, 1992