Supercritical Flow over a Dentated Sill
- 1 September 2011
- journal article
- Published by American Society of Civil Engineers (ASCE) in Journal of Hydraulic Engineering
- Vol. 137 (9) , 1019-1026
Abstract
Experimental analysis concerning supercritical flow over a dentated sill in nonsubmerged conditions and the local scour downstream of this sill is presented. In this case, the energy dissipation is incomplete so that a scour control downstream of the hydraulic structure could be required. The use of this type of dissipation device could be needed in cases where the maximum flow depth upstream of the sill must be limited to satisfy physical or structural conditions. This could happen, for instance, in the restoration of stilling basin in gravity dams and at the outlet of diversion systems. Experimental and theoretical results, useful in the design of this type of stilling basin and scour control, are presented in the paper, with an application to the case of the Molato Dam in Italy.Keywords
This publication has 11 references indexed in Scilit:
- Hydraulics of 3D Plunge Pool ScourJournal of Hydraulic Engineering, 2008
- Design of erosion protection at diversion tunnel outlets with concrete prismsCanadian Journal of Civil Engineering, 2006
- Ski Jump HydraulicsJournal of Hydraulic Engineering, 2005
- Discussion of “Effect of Jet Air Content on Plunge Pool Scour” by Stefano Canepa and Willi H. HagerJournal of Hydraulic Engineering, 2004
- Effect of Jet Air Content on Plunge Pool ScourJournal of Hydraulic Engineering, 2003
- Supercritical Flow Over a Sill in an Open ChannelJournal of Applied Mechanics and Technical Physics, 2002
- Energy Dissipators and Hydraulic Jump1992
- Discussion of “Supercritical Flow Over Sills”Journal of the Hydraulics Division, 1977
- Supercritical Flow Over SillsJournal of the Hydraulics Division, 1976
- A STUDY ON THE COMPUTATION OF HORIZONTAL DISTANCE OF JET ISSUED FROM SKI-JUMP SPILLWAYProceedings of the Japan Society of Civil Engineers, 1973