Improving Reliability of Monitoring Background EEG Dynamics in Asphyxiated Infants
- 14 September 2015
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 63 (5) , 973-983
Abstract
The goal of this study is to develop an automated algorithm to quantify background electroencephalography (EEG) dynamics in term neonates with hypoxic ischemic encephalopathy. The recorded EEG signal is adaptively segmented and the segments with low amplitudes are detected. Next, depending on the spatial distribution of the low-amplitude segments, the first part of the algorithm detects (dynamic) interburst intervals (dIBIs) and performs well on the relatively artifact-free EEG periods and well-defined burst-suppression EEG periods. However, on testing the algorithm on EEG recordings of more than 48 h per neonate, a significant number of misclassified and dubious detections were encountered. Therefore, as the next step, we applied machine learning classifiers to differentiate between definite dIBI detections and misclassified ones. The developed algorithm achieved a true positive detection rate of 98%, 97%, 88%, and 95% for four duration-related dIBI groups that we subsequently defined. We benchmarked our algorithm with an expert diagnostic interpretation of EEG periods (1 h long) and demonstrated its effectiveness in clinical practice. We show that the detection algorithm effectively discriminates challenging cases encountered within mild and moderate background abnormalities. The dIBI detection algorithm improves identification of neonates with good clinical outcome as compared to the classification based on the classical burst-suppression interburst interval.Keywords
Funding Information
- Research Council KUL (CoE PFV/10/002 (OPTEC))
- IWT: projects (TBM 110697-NeoGuard)
- IWT Postdoc
- iMinds (SBO 2015)
- Belgian Federal Science Policy Office (IUAP P7/19/)
- DYSCO
- ‘Dynamical systems, control and optimization’ (2012–2017)
- European Research Council
- ERC Advanced Grant
- BIOTENSORS (n° 339804)
This publication has 29 references indexed in Scilit:
- Line length as a robust method to detect high-activity events: Automated burst detection in premature EEG recordingsClinical Neurophysiology, 2014
- American Clinical Neurophysiology Society Standardized EEG Terminology and Categorization for the Description of Continuous EEG Monitoring in NeonatesJournal Of Clinical Neurophysiology, 2013
- Automating the analysis of EEG recordings from prematurely-born infants: A Bayesian approachClinical Neurophysiology, 2013
- Automatic burst detection for the EEG of the preterm infantPhysiological Measurement, 2011
- Quantitative EEG analysis in neonatal hypoxic ischaemic encephalopathyClinical Neurophysiology, 2011
- Validation of a new automated neonatal seizure detection system: A clinician’s perspectiveClinical Neurophysiology, 2011
- The use of conventional EEG for the assessment of hypoxic ischaemic encephalopathy in the newborn: A reviewClinical Neurophysiology, 2011
- Detection of ‘EEG bursts’ in the early preterm EEG: Visual vs. automated detectionClinical Neurophysiology, 2010
- Automatic classification of background EEG activity in healthy and sick neonatesJournal of Neural Engineering, 2010