Influence of LVAD Cannula Outflow Graft Flow Rate and Location on Fluid-Particle Interactions and Thrombi Distribution: A Primary Numerical Study
Open Access
- 22 July 2024
- journal article
- research article
- Published by Springer Nature in Journal of Cardiovascular Translational Research
- Vol. 17 (6) , 1316-1327
Abstract
A left ventricular assist device (LVAD) supports hemodynamics in heart failure patients. To deepen the understanding of hemodynamic changes and the movement of thrombi in the aorta, we examined three distinct LVAD blood flow rates across two implantation sites using the theory of computational fluid dynamics. Our findings revealed the complex dynamics of blood flow during cardiac systole under various scenarios. We also analyzed thrombi residence time and flow probabilities into aortic branches. Simulation results indicate that thrombi distribution in the aorta is significantly influenced by the location of the LVAD outflow graft and the flow rate. When the LVAD outflow graft is implanted into the ascending aorta, higher flow rates may reduce the risk of cerebral thrombosis. However, lower flow rates may reduce the risk of cerebral thrombosis while it is implanted into the descending aorta. The study may offer valuable insights into the LVAD implantation about the risk of cerebrovascular embolism. Graphical AbstractKeywords
Funding Information
- Natural Science Foundation of Hunan Province (2021JJ41002, 2019JJ50590)
- National Natural Science Foundation of China (81601728, 31500726)
This publication has 31 references indexed in Scilit:
- Multi-indicator analysis of mechanical blood damage with five clinical ventricular assist devicesComputers in Biology and Medicine, 2022
- Numerical investigation of the effects of cannula geometry on hydraulic blood flow to prevent the risk of thrombosisComputers in Biology and Medicine, 2021
- Ventricular Flow Field Visualization During Mechanical Circulatory Support in the Assisted Isolated Beating HeartAnnals of Biomedical Engineering, 2019
- In-silico evaluation of left ventricular unloading under varying speed continuous flow left ventricular assist device supportBiocybernetics and Biomedical Engineering, 2017
- Left Ventricular Assist Device Inflow Angle and Pump Positional Change Over Time Adverse Impact on Left Ventricular Assist Device FunctionThe Annals of Thoracic Surgery, 2016
- Numerical prediction of the effect of aortic Left Ventricular Assist Device outflow-graft anastomosis locationBiocybernetics and Biomedical Engineering, 2016
- Thrombotic occlusion of the ascending aorta after Toyobo LVAD implantation with descending aortic perfusion in a post-Bentall patientJournal of Artificial Organs, 2010
- Flow Residence Time and Regions of Intraluminal Thrombus Deposition in Intracranial AneurysmsAnnals of Biomedical Engineering, 2010
- Augmented Lagrangian method for constraining the shape of velocity profiles at outlet boundaries for three-dimensional finite element simulations of blood flowComputer Methods in Applied Mechanics and Engineering, 2009
- Patient-specific isogeometric fluid–structure interaction analysis of thoracic aortic blood flow due to implantation of the Jarvik 2000 left ventricular assist deviceComputer Methods in Applied Mechanics and Engineering, 2009