Smartphone-Integrated User-Friendly Electrochemical Biosensor Based on Optimized Aptamer Specific to SARS-CoV-2 S1 Protein
Open Access
Abstract
COVID-19, caused by SARS-CoV-2, has created unprecedented global health challenges, necessitating rapid and reliable diagnostic strategies. The spike (S) protein, particularly its S1 subunit, plays a critical role in viral entry, making it a prime biomarker for early detection. In this study, we present a disposable, low-cost, and portable electrochemical biosensor employing specifically optimized aptamers (Optimers) for SARS-CoV-2 S1 recognition. The sensing approach is based on aptamer–protein complex formation in solution, followed by immobilization onto pencil graphite electrodes (PGEs). The key parameters, including aptamer concentration, interaction time, redox probe concentration, and immobilization time, were systematically optimized by performing electrochemical measurement in redox probe solution containing ferri/ferrocyanide using differential pulse voltammetry (DPV) technique.Under optimized conditions, the biosensor achieved an ultralow detection limit of 18.80 ag/mL with a wide linear range (10−1–104 fg/mL) in buffer. Importantly, the sensor exhibited excellent selectivity against hemagglutinin antigen and MERS-CoV-S1 protein, while maintaining high performance in artificial saliva with a detection limit of 14.42 ag/mL. Furthermore, its integration with a smartphone-connected portable potentiostat underscores strong potential for point-of-care use. To our knowledge, this is the first voltammetric biosensor utilizing optimized aptamers (Optimers) specific to SARS-CoV-2 S1 on disposable PGEs, providing a robust and field-deployable platform for early COVID-19 diagnostics.Keywords
Funding Information
- Scientific and Technological Research Council of Türkiye (TÜBİTAK) under the 2247-A National Outstanding Researchers Program (121C270)
This publication has 24 references indexed in Scilit:
- Optimized aptamer-based next generation biosensor for the ultra-sensitive determination of SARS-CoV-2 S1 protein in saliva samplesInternational Journal of Biological Macromolecules, 2024
- Label-free electrochemical aptasensor for the detection of SARS-CoV-2 spike protein based on carbon cloth sputtered gold nanoparticlesBiosensors and Bioelectronics: X, 2022
- Electrochemical sensors for the detection of SARS-CoV-2 virusChemical Engineering Journal, 2021
- Aptamer-based electrochemical biosensor for rapid detection of SARS-CoV-2: Nanoscale electrode-aptamer-SARS-CoV-2 imaging by photo-induced force microscopyBiosensors and Bioelectronics, 2021
- An electrochemical dual-aptamer biosensor based on metal-organic frameworks MIL-53 decorated with Au@Pt nanoparticles and enzymes for detection of COVID-19 nucleocapsid proteinElectrochimica Acta, 2021
- Diagnostics for SARS-CoV-2 detection: A comprehensive review of the FDA-EUA COVID-19 testing landscapeBiosensors and Bioelectronics, 2020
- Structural and Functional Basis of SARS-CoV-2 Entry by Using Human ACE2Cell, 2020
- Aptamer in Bioanalytical ApplicationsAnalytical Chemistry, 2011
- Aptamer-based biosensorsTrAC Trends in Analytical Chemistry, 2008
- Aptamers as therapeutic and diagnostic agentsReviews in Molecular Biotechnology, 2000