Remote Photoplethysmography With an EEMD-MCCA Method Robust Against Spatially Uneven Illuminations
- 22 March 2021
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 21 (12) , 13484-13494
Abstract
Remote photoplethysmography (rPPG) is an attractive video-based technique to monitor heart rate (HR) information in telehealth screening. The subjects are required to stay stationary in the remote screening scenario and ambient lights become the main interference source of measuring HR with rPPG. In this paper, we introduce a novel approach robust against spatially uneven illumination interference in rPPG by combining ensemble empirical mode decomposition (EEMD) with multiset canonical correlation analysis (MCCA). We adopt the following procedures to ensure that the pulses dominate the correlations across multiple signal sets while the illumination noises are as diverse as possible. Specifically, a group of optimal regions of interest (ROIs) are selected according to the quality indicators defined from the green channel in each candidate ROI. A multi-channel signal set is then constructed by decomposing the green signal with EEMD. Only those intrinsic mode functions (IMFs) with the dominant frequencies falling into the interested HR range are utilized as the input of MCCA. The canonical variables (CVs) with the highest cross correlations are derived as the underlying candidate pulses. Finally, fast Fourier transform (FFT) is employed to calculate the dominant frequency and the target HR is determined based on both the quasi-periodic property and the continuity of HR. The proposed EEMD-MCCA method is validated on both the in-house BSIPL-RPPG and the public COHFACE databases, which achieves superior performance over several typical rPPG methods. This study will provide a promising tool for realistic rPPG applications in telehealth screening.Keywords
Funding Information
- National Natural Science Foundation of China (61922075, 41901350)
- Provincial Natural Science Foundation of Anhui (2008085QF285)
- Fundamental Research Funds for the Central Universities (JZ2019HGBZ0151)
This publication has 42 references indexed in Scilit:
- On the computational complexity of the empirical mode decomposition algorithmPhysica A: Statistical Mechanics and its Applications, 2014
- Effect of measurement duration on accuracy of pulse-countingErgonomics, 2013
- Remote Measurements of Heart and Respiration Rates for TelemedicinePLOS ONE, 2013
- Robust Pulse Rate From Chrominance-Based rPPGIEEE Transactions on Biomedical Engineering, 2013
- ROI Selection for Remote Photoplethysmography2013
- Motion-compensated noncontact imaging photoplethysmography to monitor cardiorespiratory status during exerciseJournal of Biomedical Optics, 2011
- Non-contact, automated cardiac pulse measurements using video imaging and blind source separationOptics Express, 2010
- ENSEMBLE EMPIRICAL MODE DECOMPOSITION: A NOISE-ASSISTED DATA ANALYSIS METHODAdvances in Adaptive Data Analysis, 2009
- A NEW VIEW OF NONLINEAR WATER WAVES: The Hilbert SpectrumAnnual Review of Fluid Mechanics, 1999
- Canonical Analysis of Several Sets of VariablesBiometrika, 1971