Centration and Coverage of Hydrogel Contact Lenses

Authors:
  • EWEugene Wake
    Eugene Wake
  • JTJuan B. L. Tienda
    Juan B. L. Tienda
  • PUPatricia M. Uyekawa
    Patricia M. Uyekawa
  • RMRobert B. Mandell
    Robert B. Mandell

Abstract
Decentration of the AOsoft lenses and Bausch & Lomb Soflens occurs during wear. The extent of the decentration of 14 lenses on 36 eyes of 18 subjects was studied by means of a biomicroscope with a reticle mounted in the ocular. Unexpectedly, for the AOsoft vault IV lens greater decentration occurred than for flatter lenses. Corneal toricity showed no correlation with lens decentration.