Three-port (one incision plus two-port) endoscopic mitral valve surgery without robotic assistance†
Authors:
- Toshiaki ItoTIToshiaki Ito
- Atsuo MaekawaAMAtsuo Maekawa
- Satoshi HoshinoSHSatoshi Hoshino
- Yasunari HayashiYHYasunari Hayashi
- Sadanari SawakiSSSadanari Sawaki
- Junji YanagisawaJYJunji Yanagisawa
- Masayoshi TokoroMTMasayoshi Tokoro
Open Access
- 17 March 2017
- journal article
- research article
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 51 (5) , 913-918
Abstract
OBJECTIVES: Totally endoscopic minimally invasive mitral valve surgery (MIMVS) is technically demanding and often performed with robotic assistance. We hypothesized that three-port video-assisted thoracic surgery (VATS) would facilitate endoscopic MIMVS and evaluated its feasibility and safety. METHODS: From October 2010 to June 2016, we performed first-time MIMVS in 250 consecutive patients (122 male), with median age of 65 years (54–73 years, 25–75 percentile). The thoracic access ports comprised one small (3–5 cm) thoracotomy without a rib spreader plus two trocars (one for the endoscope and one for left-handed instruments), thus establishing triangular three-port VATS. Cannulas, an aortic clamp, and a left atrial retractor were inserted through the thoracotomy, and right-handed instruments were inserted through the remaining space. Cardiopulmonary bypass was established through a groin incision. RESULTS: The etiology of the mitral valve lesion was myxomatous degeneration in 70% of patients, rheumatic disease in 9%, infectious endocarditis in 6%, and other conditions in 15%. Mitral valve repair was performed in 233 patients and replacement in 27. Two patients underwent conversion to replacement after attempted repair. Forty-nine patients underwent tricuspid annuloplasty, and 45 underwent the Maze procedure. One in-hospital death occurred within 30 days. Two patients developed stroke, three underwent re-exploration for bleeding, one developed low output syndrome, and one required new haemodialysis. The aortic clamp, bypass, and total operation times were 119 (94–149), 166 (134–200) and 237 (204–285) min, respectively, median (25–75%). The 5-year survival and reoperation-free rates were 98.3% ± 0.9% and 96.9% ± 1.2%, respectively. CONCLUSIONS: Three-port endoscopic MIMVS appears reproducible and safe.Keywords
This publication has 10 references indexed in Scilit:
- A propensity matched comparison of effects between video assisted thoracoscopic single-port, two-port and three-port pulmonary resection on lung cancerJournal of Thoracic Disease, 2016
- Robotic Mitral Valve Repair for Simple and Complex Degenerative DiseaseCirculation, 2015
- Thoracic and cardiovascular surgery in Japan during 2013General Thoracic and Cardiovascular Surgery, 2015
- The Expanding Role of Endoscopic Robotics in Mitral Valve Surgery: 1,257 Consecutive ProceduresThe Annals of Thoracic Surgery, 2015
- Minimally invasive mitral valve surgery through right mini-thoracotomy: recommendations for good exposure, stable cardiopulmonary bypass, and secure myocardial protectionGeneral Thoracic and Cardiovascular Surgery, 2015
- Mitral durability after robotic mitral valve repair: Analysis of 200 consecutive mitral regurgitation repairsThe Journal of Thoracic and Cardiovascular Surgery, 2014
- Three hundred robotic-assisted mitral valve repairs: The Cedars-Sinai experienceThe Journal of Thoracic and Cardiovascular Surgery, 2014
- Learning Minimally Invasive Mitral Valve SurgeryCirculation, 2013
- Post-thoracotomy pain and long-term survival associated with video-assisted thoracic surgery lobectomy methods for clinical T1N0 lung cancer: a patient-oriented, prospective cohort studyEuropean Journal of Cardio-Thoracic Surgery, 2013
- Thoracoscopic Versus Open Mitral Valve Repair: A Propensity Score Analysis of Early OutcomesThe Annals of Thoracic Surgery, 2009