The Role of Different Feedback Devices in the Survival of Patients in Cardiac Arrest: Systematic Review with Meta-Analysis
Authors:
- Luca GambolòLGLuca Gambolò
- Pasquale Di FronzoPFPasquale Di Fronzo
- Giuseppe RistagnoGRGiuseppe Ristagno
- Sofia BiserniSBSofia Biserni
- Martina MilazzoMMMartina Milazzo
- Delia Marta SocaciDSDelia Marta Socaci
- Leopoldo SarliLSLeopoldo Sarli
- Giovanna ArtioliGiovanna Artioli
- Antonio BonacaroAntonio Bonacaro
- Giuseppe StirparoGSGiuseppe Stirparo
Open Access
- 8 October 2024
- journal article
- review article
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 13 (19) , 5989
Abstract
Background: Cardiac arrest is a critical condition affecting approximately 1 in every 1000 people in Europe. Feedback devices have been developed to enhance the quality of chest compressions during CPR, but their clinical impact remains uncertain. This study aims to evaluate the effect of feedback devices on key clinical outcomes in adult patients experiencing both out-of-hospital (OHCA) and in-hospital cardiac arrest (IHCA). The primary objective is to assess their impact on the return of spontaneous circulation (ROSC); secondary objectives include the evaluation of neurological status and survival to discharge. Methods: A systematic review was conducted following PRISMA guidelines, utilizing databases including PubMed, Scopus, Web of Science, and Embase. Studies published between 2000 and 2023 comparing CPR with and without the use of feedback devices were included. A fixed-effects network meta-analysis was performed for ROSC and survival, while a frequentist meta-analysis was conducted for neurological outcomes. Results: Twelve relevant studies met the inclusion criteria. The meta-analysis results showed that the use of audiovisual feedback devices significantly increases the likelihood of ROSC (OR 1.26, 95% CI 1.13–1.41, p < 0.0001) and survival (OR 1.52, 95% CI 1.27–1.81, p < 0.0001) compared to CPR without feedback. However, the effect of metronomes did not reach statistical significance. Conclusions: Feedback devices, particularly audiovisual ones, are associated with improved clinical outcomes in cardiac arrest patients. Their use should be encouraged in both training settings and real-life emergency scenarios to enhance survival rates and ROSC. However, further studies are needed to confirm long-term impacts and to explore the potential benefits of metronomes.Keywords
This publication has 37 references indexed in Scilit:
- In-Hospital Cardiac ArrestEmergency Medicine Clinics of North America, 2023
- Survival to Intensive Care Unit Discharge Among in-Hospital Cardiac Arrest Patients by Applying Audiovisual Feedback DeviceESC Heart Failure, 2021
- Do automated real-time feedback devices improve CPR quality? A systematic review of literatureResuscitation Plus, 2021
- Cardiopulmonary Resuscitation Feedback: A Comparison of Device-Measured and Self-Assessed Chest Compression QualityJournal of Emergency Nursing, 2021
- In-Hospital Cardiac ArrestJAMA, 2019
- Improving CPR PerformanceChest, 2017
- Real-time feedback can improve infant manikin cardiopulmonary resuscitation by up to 79%—A randomised controlled trialResuscitation, 2013
- Chest compression quality management and return of spontaneous circulation: A matched-pair registry studyResuscitation, 2012
- CPR quality improvement during in-hospital cardiac arrest using a real-time audiovisual feedback systemResuscitation, 2007
- Quality of out-of-hospital cardiopulmonary resuscitation with real time automated feedback: A prospective interventional studyResuscitation, 2006