Early experience in using and 18 Me V linear accelerator for mycosis fungoides at Howard University Hospital.
Authors:
- P P KumarPKP P Kumar
- K HenschkeKHK Henschke
- K P MandalKMK P Mandal
- J R NibhanupudyJNJ R Nibhanupudy
- I S PatelIPI S Patel
- 1 April 1977
- journal article
- Vol. 69 (4) , 223-6
Abstract
This paper describes the problems and solutions in using 18 MeV linear accelerator, with minimum 6 MeV electron capability, for total skin irradiation for mycosis fungoides. The 6 MeV electron energy can be degraded to acceptable electron energy of 3.2 MeV by interposing a plexiglass sheet of 9.6 mm in the beam. To minimize the bremsstrahlung, the degrading plexiglass should be kept away from the machine head. A wide area with uniform dose distribution over single plane can be achieved by using dual fields but homogenous dose distribution over irregular body surface cannot be achieved mainly because of self-shielding. The nails and the ocular lens can be easily shielded from the low energy electrons with 1.5 mm lead shield.Keywords
This publication has 11 references indexed in Scilit:
- Mycosis fungoides with extracutaneous dissemination: A distinct clinicopathologic entityCancer, 1974
- Mycosis fungoides: Pathologic findings in staging laparotomiesCancer, 1974
- Dosimetry for Total-Body Electron-Beam Therapy in the Treatment of Mycosis FungoidesRadiology, 1973
- Total-Skin Electron Treatment of Mycosis FungoidesRadiology, 1971
- Patient Dosimetry in the Electron Treatment of Large Superficial LesionsRadiology, 1970
- Total-Skin Electron-Beam Therapy of Lymphoma Cutis and Generalized Psoriasis: Clinical Experiences and Adverse ReactionsRadiology, 1966
- X-Ray Contamination in Total-Skin Electron Therapy of Lymphoma Cutis and Exfoliative DermatitisRadiology, 1965
- Ten year experience with low megavolt ellectron therapy.1962
- 10 mev. betatron electron beam therapy adapted to a case of mycosis fungoides.1962
- High energy electrons for the treatment of extensive superficial malignant lesions.1953