Background Multiplanar complex C3-type unstable distal femoral fractures present many challenges in terms of approach and fixation. This prospective study investigates a possible solution to these problems through double plating with autogenous bone grafting via a modified Olerud extensile approach. Materials and methods Twelve patients with closed C3-type injuries were included; eight of them were male, and their mean age was 33.5 years (range 22–44 years). Mechanism of injury was road traffic accident (RTA) in nine patients and fall from height in the other three cases. Eight cases were operated during the first week and four cases during the second week after injury. Mean follow-up was 13.7 months (range 11–18 months). Results Mean radiological healing time was 18.3 weeks (range 12-28 weeks), and all cases had good radiological healing without recorded nonunion or malunion. Clinically, two cases (16.7 %) had excellent results, five cases (41.7 %) had good results, three cases (25 %) had fair results, and two cases (16.7 %) had poor results. No cases developed skin necrosis, deep infection, bone collapse, or implant failure. However, two cases (16.7 %) had limited knee flexion to 90° and required subsequent quadricepsplasty. Conclusions Use of this modified highly invasive approach facilitated anatomical reconstruction of C3-type complex distal femoral fractures with lower expected complication rate and acceptable clinical outcome, especially offering good reconstruction of the suprapatellar pouch area. It can be considered as a standby solution for managing these difficult injuries.Keywords
This publication has 31 references indexed in Scilit:
- Pitfalls in the Application of Distal Femur Plates for FracturesJournal of Orthopaedic Trauma, 2011
- Minimally-invasive fixation of distal extra-articular femur fractures with locking plates: Limitations and failuresOrthopaedics & Traumatology: Surgery & Research, 2011
- Outcome analysis of retrograde nailing and less invasive stabilization system in distal femoral fractures: A retrospective analysisIndian Journal of Orthopaedics, 2011
- 2010 Mid-America Orthopaedic Association Physician in Training Award: Healing Complications Are Common After Locked Plating for Distal Femur FracturesClinical Orthopaedics and Related Research, 2011
- Lower limb malrotation following MIPO technique of distal femoral and proximal tibial fracturesInjury, 2011
- Locked Plating of Distal Femur Fractures Leads to Inconsistent and Asymmetric Callus FormationJournal of Orthopaedic Trauma, 2010
- The clinical and radiological outcomes of the LISS plate for distal femoral fractures: A systematic reviewInjury, 2009
- Cruciate fracture of the distal femur: the double Hoffa fractureInjury, 2004
- Distal femoral fractures: long-term outcome following stabilisation with the LISSInjury, 2004
- Ilizarov external fixation for severely comminuted supracondylar and intercondylar fractures of the distal femurThe Journal of Bone and Joint Surgery. British volume, 2001