Outcome and serum ion determination up to 11 years after implantation of a cemented metal-on-metal hip prosthesis
Open Access
- 1 January 2009
- journal article
- research article
- Published by Medical Journals Sweden AB in Acta Orthopaedica
- Vol. 80 (2) , 168-173
Abstract
Background and purpose Little is known about the long-term outcome of cemented metal-on-metal hip arthroplasties. We evaluated a consecutive series of metal-on-metal polyethylene-backed cemented hip arthroplasties implanted in patients under 60 years of age. Methods 109 patients (134 joint replacements) were followed prospectively for mean 9 (7–11) years. The evaluation included clinical score, radiographic assessment, and blood sampling for ion level determination. Results At the final review, 12 hips had been revised, mainly because of aseptic loosening of the socket. Using revision for aseptic loosening as the endpoint, the survival rate at 9 years was 91% for the cup and 99% for the stem. In addition, 35 hips showed radiolucent lines at the bone-cement interface of the acetabulum and some were associated with osteolysis. The median serum cobalt and chromium levels were relatively constant over time, and were much higher than the detection level throughout the study period. The cobalt level was 1.5 μg/L 1 year after implantation, and 1.44 μg/L 9 years after implantation. Interpretation Revisions for aseptic loosening and radiographic findings in the sockets led us to halt metal-on-metal-backed polyethylene cemented hip arthroplasty procedures. If the rigidity of the cemented socket is a reason for loosening, excessive release of metal ions and particles may be involved. Further investigations are required to confirm this hypothesis and to determine whether subluxation, microseparation, and hypersensitivity also play a role.Keywords
This publication has 25 references indexed in Scilit:
- Clinical and biological assessment of cemented titanium femoral stems: an 11-year experienceInternational Orthopaedics, 2008
- Long‐term follow‐up of metal‐on‐metal total hip replacementJournal of Orthopaedic Research, 2007
- Characterisation of wear particles produced by metal on metal and ceramic on metal hip prostheses under standard and microseparation simulationJournal of Materials Science: Materials in Medicine, 2006
- Midterm Results of Metasul Metal-on-Metal Total Hip ArthroplastyThe Journal of Arthroplasty, 2006
- Serum Metal Levels and Bearing Surfaces in Total Hip ArthroplastyThe Journal of Arthroplasty, 2006
- Effect of swing phase load on metal-on-metal hip lubrication, friction and wearJournal of Biomechanics, 2005
- Development and validation of a second-generation metal-on-metal bearingThe Journal of Arthroplasty, 2004
- Comparison of in vitro with in vivo characteristics of wear particles from metal–metal hip implantsJournal of Biomedical Materials Research Part B: Applied Biomaterials, 2004
- Wear Behavior and Histopathology of Classic Cemented Metal on Metal Hip EndoprosthesesClinical Orthopaedics and Related Research, 1996
- Experience With the Metasul Total Hip Bearing SystemClinical Orthopaedics and Related Research, 1996