Heat-resistant cylindrical diffuser for interstitial laser coagulation: Comparison with the bare-tip fiber in a porcine liver model
Authors:
- 1 January 1997
- journal article
- research article
- Published by Wiley in Lasers in Surgery and Medicine
- Vol. 20 (3) , 304-309
Abstract
Interstitial laser coagulation is an experimental treatment to eliminate solid tumors such as hepatic metastases. The pattern of light emission from the fiber tip is probably an important factor in determining the size and shape of a lesion. A heat-resistant cylindrical light diffusing tip of 2 cm length was developed for this application. We performed an in vitro study to compare this diffusing-tip with a bare-tip fiber. Study Design/Materials and Methods: Fiber ends were positioned between two porcine liver slabs (37°C) and Nd:YAG laser light (1064 nm) was guided through either fiber with an output of 3–9 W and exposure times of 6–18 minutes. Lesions produced by the cylindrical diffuser tip were significantly larger and more predictable. With the diffuser tip, lesions up to 36/23 mm (length/width) could be produced at 7 W and 9 min without any central charring. The maximum size of lesions produced with the bare-tip fiber was 32/20 mm at 6 W for 9 min with massive charring. The results indicate that at optimal laser settings, the diffuser tip produces a larger coagulation volume than a bare-tip fiber. For clinical application, cylindrical diffusing fibers should be used with a diffusing length adapted to the diameter of the tumor. Lasers Surg. Medicine 20:304–309, 1997.Keywords
This publication has 13 references indexed in Scilit:
- Interstitial laser photocoagulation as treatment for breast cancerBritish Journal of Surgery, 1995
- Development of an application set for intraoperative and percutaneous laser-induced interstitial thermotherapy (LITT)1994
- Interstitial laser photocoagulation as a treatment for breast cancerBritish Journal of Surgery, 1994
- Dependence of laser photocoagulation on interstitial delivery parametersLasers in Surgery and Medicine, 1994
- Interstitial laser photocoagulation: Evaluation of a 1320 nm Nd-YAG and an 805 nm diode laser: the significance of charring and the value of precharring the fibre tipLasers in Medical Science, 1993
- Selecting source locations in multifiber interstitial laser photocoagulationLasers in Surgery and Medicine, 1993
- Interstitial laser hyperthermiaSeminars in Surgical Oncology, 1992
- Interstitial laser photocoagulation: Nd:YAG 1064 nm optical fiber source compared to point heat sourceLasers in Surgery and Medicine, 1992
- PATHOLOGIC ANALYSIS OF PHOTOTHERMAL AND PHOTOMECHANICAL EFFECTS OF LASER–TISSUE INTERACTIONSPhotochemistry and Photobiology, 1991
- Biological effects of intrahepatic neodymium: Yttrium-aluminum-garnet laser photocoagulation in ratsGastroenterology, 1987