Amperometric biosensor for hydrogen peroxide based on immobilisation of haemoglobin on mesoporous zirconia
Authors:
- 18 August 2011
- journal article
- research article
- Published by Taylor & Francis in International Journal of Environmental Analytical Chemistry
- Vol. 91 (14) , 1367-1379
Abstract
A novel hydrogen peroxide biosensor has been presented based on fabricating mesoporous ZrO2 and haemoglobin (mesoZrO2-Hb) film onto gold electrode surface through coelectrodeposition. FT-IR and UV–vis spectroscopy demonstrated that haemoglobin (Hb) in the mesoporous ZrO2 (mesoZrO2) matrix could retain its native secondary structure. Transmission electron microscopy (TEM) image and N2 adsorption/desorption isotherm showed that the obtained mesoZrO2 presented disordered porous structure and appropriate pore size that was suitable for the immobilisation of Hb. The performance and factors influencing the resulting biosensor were studied in detail by means of cyclic voltammetry (CV) and chronoamperometry. Analytical parameters such as pH and applied potential were also studied. The electrochemical parameters of Hb in the mesoZrO2 matrix were calculated with the results of the electron transfer coefficient (α) and the apparent heterogeneous electron transfer rate constant ( ) as 0.64 and 1.47 s−1 respectively, indicating good facilitation of the electron transfer between Hb and the modified electrode. The immobilised Hb retained its biological activity well and showed high catalytic activity to the reduction of hydrogen peroxide (H2O2). And the linear range was from 1.75 × 10−7 to 4.9 × 10−3 mol L−1 with a detection limit of 1.0 × 10−7 mol L−1 (S/N = 3). In addition, the studied biosensor exhibited high sensitivity, good reproducibility and stability.Keywords
This publication has 35 references indexed in Scilit:
- Direct electrochemistry and electrocatalysis of horseradish peroxidase immobilized in sol–gel-derived ceramic–carbon nanotube nanocomposite filmBiosensors and Bioelectronics, 2007
- A novel and simple biomolecules immobilization method: Electro-deposition ZrO2 doped with HRP for fabrication of hydrogen peroxide biosensorJournal of Biotechnology, 2007
- Enzyme-Responsive Release of Encapsulated Proteins from Biodegradable Hollow CapsulesBiomacromolecules, 2006
- Challenges in biocatalysis for enzyme-based biofuel cellsBiotechnology Advances, 2006
- Heme protein-gluten films: voltammetric studies and their electrocatalytic propertiesAnalytica Chimica Acta, 2003
- Amperometric biosensor based on a nanoporous ZrO2 matrixAnalytica Chimica Acta, 2003
- l-Lactate oxidase electrode based on methylene green and carbon pasteAnalytica Chimica Acta, 1993
- Rotating ring-disk enzyme electrode for biocatalysis kinetic studies and characterization of the immobilized enzyme layerAnalytical Chemistry, 1980
- The Determination of Pore Volume and Area Distributions in Porous Substances. I. Computations from Nitrogen IsothermsJournal of the American Chemical Society, 1951
- Adsorption of Gases in Multimolecular LayersJournal of the American Chemical Society, 1938