The NOVA Score: A Proposal to Reduce the Need for Transesophageal Echocardiography in Patients With Enterococcal Bacteremia
Authors:
- Emilio BouzaEBEmilio Bouza
- Martha KestlerMKMartha Kestler
- Javier BermejoJBJavier Bermejo
- Ana Fernández-CruzAna Fernández-Cruz
- Francisco Fernández-AvilésFFFrancisco Fernández-Avilés
- Patricia MuñozPMPatricia Muñoz
- For The Grupo de Apoyo al Manejo de la EndocarditisFEFor The Grupo de Apoyo al Manejo de la Endocarditis
- E. B. SantiagoESE. B. Santiago
- P. D. VillanuevaPVP. D. Villanueva
Open Access
- 7 November 2014
- journal article
- research article
- Published by Oxford University Press (OUP) in Clinical Infectious Diseases
- Vol. 60 (4) , 528-535
Abstract
Depending on the local prevalence of endocarditis, the NOVA prediction score (Number of positive blood cultures, Origin of the bacteremia, previous Valve disease, Auscultation of heart murmur) may safely obviate echocardiography in 14%–27% of patients with enterococcal bacteremia. Background. Frequency of enterococcal bloodstream infection (E-BSI) is increasing, and the number of episodes complicated by infective endocarditis (IE) varies. Performing transesophageal echocardiography (TEE) in all patients with E-BSI is costly and time-consuming. Our objectives were to identify patients with E-BSI who are at very low risk of enterococcal IE (and therefore do not require TEE) and to compare the outcome of E-BSI in patients with/without IE. Methods. Between September 2003 and October 2012, we performed a prospective cohort study (all patients with E-BSI) and a case-control study (patients with/without enterococcal IE) in our center. Results. We detected 1515 patients with E-BSI and 65 with enterococcal IE (4.29% of all episodes of E-BSI, 16.7% of patients with E-BSI who underwent transthoracic echocardiography, and 35.5% of all patients with E-BSI who underwent TEE). We developed a bedside predictive score for enterococcal IE—Number of positive blood cultures, Origin of the bacteremia, previous Valve disease, Auscultation of heart murmur (NOVA) score—based on the following variables: Number of positive blood cultures (3/3 blood cultures or the majority if more than 3), 5 points; unknown Origin of bacteremia, 4 points; prior heart Valve disease, 2 points; Auscultation of a heart murmur, 1 point (receiver operating characteristic = 0.83). The best cutoff corresponded to a score ≥4 (sensitivity, 100%; specificity, 29%). A score Conclusions. Enterococcal IE may be more frequent than generally thought. Depending on local prevalence of endocarditis, application of the NOVA score may safely obviate echocardiography in 14%–27% of patients with E-BSI.Keywords
This publication has 24 references indexed in Scilit:
- The Value of Combining Blood Culture and SeptiFast Data for Predicting Complicated Bloodstream Infections Caused by Gram-Positive Bacteria or Candida SpeciesJournal of Clinical Microbiology, 2013
- Bloodstream InfectionsMedicine, 2008
- Infective EndocarditisCirculation, 2005
- Echocardiography in infective endocarditisHeart, 2004
- Risk Factors for Infective Endocarditis in Patients with Enterococcal Bacteremia: A Case-Control StudyInfection, 2004
- Nosocomial enterococcal endocarditis: a serious hazard for hospitalized patients with enterococcal bacteraemiaJournal of Internal Medicine, 2002
- An Analysis of 110 Serious Enterococcal Infections Epidemiology, Antibiotic Susceptibility, and OutcomeMedicine, 1995
- Pathogenicity of the Enterococcus in Surgical InfectionsAnnals of Surgery, 1990
- Enterococcal bacteremia in two large community teaching hospitalsThe American Journal of Medicine, 1986
- Enterococcal Bacteremia Clinical Implications and Determinants of DeathAnnals of Surgery, 1982