Optimization of b value in diffusion‐weighted MRI for characterization of benign and malignant gynecological lesions
Open Access
- 8 November 2011
- journal article
- research article
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 35 (3) , 650-659
Abstract
Purpose: To explore the optimal b value in diffusion‐weighted (DW)‐MRI for differentiation of benign and malignant gynecological lesions.Materials and Methods: Consecutive 58 patients (66 lesions) with pathologically confirmed diagnosis of gynecological disease were included in the study. Routine pelvic MRI sequences were used for defining the lesions and reviewed independently for benignity/ malignity. Single‐shot echoplanar imaging (SH‐EPI) DW‐MRI with eight b values and nine apparent diffusion coefficient (ADC) maps were obtained. The lesions were analyzed qualitatively on DW‐MRI for benignity/malignity on a five‐point‐scale and quantitatively by measurement of apparent diffusion coefficient (ADC) values. Receiver operating characteristic (ROC) analysis was used to evaluate the diagnostic accuracy of ADC values for differentiating between benign and malignant lesions. Pathology results were the reference standard.Results: Differentiation between benign and malignant gynecological lesions using visual scoring was found to be successful with b values of 600, 800, or 1000 s/mm2. The mean ADC values of malignant lesions were significantly lower than those of benign lesions for all b value (P < 0.005). The ADCs with b = 0 and 600, 0 and 1000 s/mm2, 0, 600, 800 and 1000 s/mm2, and all b values were more effective for distinguishing malignant from benign gynecological lesions (Az = 0.851, 0.847, 0.848, 0.849, respectively). Using ADC with b = 0, 600, 800, and 1000 s/mm2, a threshold value of 1.20 × 10−3 mm2/s permitted this distinction with a sensitivity of 83%, a specificity of 81%.Conclusion: DW‐MRI is an important method, and the optimal b values are between 600 and 1000 s/mm2 for differentiation between benign and malignant gynecological lesions. J. Magn. Reson. Imaging 2012;35:650‐659.Keywords
This publication has 27 references indexed in Scilit:
- The influence of the b‐value combination on apparent diffusion coefficient based differentiation between malignant and benign tissue in cervical cancerJournal of Magnetic Resonance Imaging, 2010
- Diffusion-Weighted Magnetic Resonance Imaging of Uterine Cervical CancerJournal of Computer Assisted Tomography, 2009
- Diffusion-weighted Imaging in the Abdomen and Pelvis: Concepts and ApplicationsRadioGraphics, 2009
- Pitfalls in Abdominal Diffusion-Weighted Imaging: How Predictive is Restricted Water Diffusion for MalignancyAmerican Journal of Roentgenology, 2009
- Diffusion-weighted MR Imaging of Female Pelvic Tumors: A Pictorial ReviewRadioGraphics, 2009
- Diffusion-weighted Imaging in Cervical Cancer with an Endovaginal Technique: Potential Value for Improving Tumor Detection in Stage Ia and Ib1 DiseaseRadiology, 2008
- Role of diffusion-weighted imaging in the diagnosis of gynecological diseasesEuropean Radiology, 2008
- Diffusion-weighted MRI in cervical cancerEuropean Radiology, 2008
- Diffusion‐weighted MRI (DWI) in the oncology patient: Value of breathhold DWI compared to unenhanced and gadolinium‐enhanced MRIJournal of Magnetic Resonance Imaging, 2007
- Apparent diffusion coefficient in cervical cancer of the uterus: comparison with the normal uterine cervixEuropean Radiology, 2004