Lateral drill holes decrease strength of the femur: an observational study using finite element and experimental analyses
Open Access
- 30 August 2013
- journal article
- research article
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 8 (1) , 29
Abstract
Background: Internal fixation of femoral fractures requires drilling holes through the cortical bone of the shaft of the femur. Intramedullary suction reduces the fat emboli produced by reaming and nailing femoral fractures but requires four suction portals to be drilled into the femoral shaft. This work investigated the effect of these additional holes on the strength of the femur. Methods: Finite element analysis (FEA) was used to calculate compression, tension and load limits which were then compared to the results from mechanical testing. Models of intact femora and fractured femora internally fixed with intramedullary nailing were generated. In addition, four suction portals, lateral, anterior and posterior, were modelled. Stresses were used to calculate safety factors and predict fatigue. Physical testing on synthetic femora was carried out on a universal mechanical testing machine. Results: The FEA model for stresses generated during walking showed tensile stresses in the lateral femur and compression stresses in the medial femur with a maximum sheer stress through the neck of the femur. The lateral suction portals produced tensile stresses up to over 300% greater than in the femur without suction portals. The anterior and posterior portals did not significantly increase stresses. The lateral suction portals had a safety factor of 0.7, while the anterior and posterior posts had safety factors of 2.4 times walking loads. Synthetic bone subjected to cyclical loading and load to failure showed similar results. On mechanical testing, all constructs failed at the neck of the femur. Conclusions: The anterior suction portals produced minimal increases in stress to loading so are the preferred site should a femur require such drill holes for suction or internal fixation.Keywords
This publication has 34 references indexed in Scilit:
- Reamer-irrigator-aspirator indications and clinical results: a systematic reviewInternational Orthopaedics, 2011
- Monitoring and controlling intramedullary pressure increase in long bone instrumentation: A study on sheepJournal of Orthopaedic Research, 2008
- Effect of re-implanted particles from intramedullary reaming on mechanical properties and callus formationThe Journal of Bone and Joint Surgery. British volume, 2007
- Cortical Heat Generation Using An Irrigating/Aspirating Single-Pass Reaming vs Conventional Stepwise ReamingJournal of Orthopaedic Trauma, 2007
- The Biomechanics of Human Femurs in Axial and Torsional Loading: Comparison of Finite Element Analysis, Human Cadaveric Femurs, and Synthetic FemursJournal of Biomechanical Engineering, 2006
- Femur Fractures and Lung ComplicationsClinical Orthopaedics and Related Research, 2004
- Effect of Proximal and Distal Venting During Intramedullary NailingClinical Orthopaedics and Related Research, 1996
- Coulomb frictional interfaces in modeling cemented total hip replacements: A more realistic modelJournal of Biomechanics, 1995
- Pulmonary microvascular fatCritical Care Medicine, 1993
- Finite-element-analysis and experimental investigation of stresses in a femurJournal of Biomedical Engineering, 1982