Cardiac CT motion artifact grading via semi-automatic labeling and vessel tracking using synthetic image-augmented training data
Authors:
- 15 April 2022
- journal article
- research article
- Published by SAGE Publications in Journal of X-Ray Science and Technology
- Vol. 30 (3) , 433-445
Abstract
Cardiac CT provides critical information for the evaluation of cardiovascular diseases. However, involuntary patient motion and physiological movement of the organs during CT scanning cause motion blur in the reconstructed CT images, degrading both cardiac CT image quality and its diagnostic value. In this paper, we propose and demonstrate an effective and efficient method for CT coronary angiography image quality grading via semi-automatic labeling and vessel tracking. These algorithms produce scores that accord with those of expert readers to within 0.85 points on a 5-point scale. We also train a neural network model to perform fully-automatic motion artifact grading. We demonstrate, using XCAT simulation tools to generate realistic phantom CT data, that supplementing clinical data with synthetic data improves the scoring performance of this network. With respect to ground truth scores assigned by expert operators, the mean square error of grading motion of the right coronary artery is reduced by 36% by synthetic data supplementation. This demonstrates that augmentation of clinical training data with realistically synthesized images can potentially reduce the number of clinical studies needed to train the network.Keywords
This publication has 20 references indexed in Scilit:
- A review of heart chamber segmentation for structural and functional analysis using cardiac magnetic resonance imagingMagnetic Resonance Materials in Physics, Biology and Medicine, 2016
- Cardiac motion correction based on partial angle reconstructed images in x‐ray CTMedical Physics, 2015
- 4D XCAT phantom for multimodality imaging researchMedical Physics, 2010
- Coronary artery disease in 2010European Heart Journal Supplements, 2010
- Estimated Radiation Dose Associated With Cardiac CT AngiographyJAMA, 2009
- Four-Chamber Heart Modeling and Automatic Segmentation for 3-D Cardiac CT Volumes Using Marginal Space Learning and Steerable FeaturesIEEE Transactions on Medical Imaging, 2008
- Computed Tomography — An Increasing Source of Radiation ExposureNew England Journal of Medicine, 2007
- Image quality assessment: from error visibility to structural similarityIEEE Transactions on Image Processing, 2004
- Strategies for CT Radiation Dose OptimizationRadiology, 2004
- Cardiovascular disease risk profilesAmerican Heart Journal, 1991