Comprehensive Cost–Energy Evaluation of Wall Insulation for Diverse Orientations and Seasonal Usages
Open Access
- 12 September 2024
- journal article
- research article
- Published by MDPI AG in Applied Sciences
- Vol. 14 (18) , 8239
Abstract
An optimization study on thermal insulation applied to building exteriors has been performed in this research. Solar radiation has been considered while obtaining optimum insulation thicknesses for various directions. Analyses have been conducted not only for the cardinal directions (south, north, west, and east) but also for the intermediate directions (southeast, northeast, northwest, and southwest). Solar radiation received by vertical walls and cooling and heating degree day values have been computed according to directions. This research examines the most suitable insulation thicknesses for different seasonal usage scenarios, considering cooling, heating, and annual energy demands. Variations in energy cost savings, savings rates, payback periods, seasonal energy demands, and optimum insulation thicknesses for various wall orientations have been presented. Additionally, correlations providing the total cost based on the applied insulation thickness for each direction and various building usage scenarios have been determined. The results indicate that incoming solar radiation varies from 52.08 W/m2 to 111.82 W/m2 across different wall orientations, while energy cost savings range from 23.48 USD/m2 to 24.56 USD/m2, with savings rates between 69.8% and 70.3%. Payback periods range from 5.94 to 6.05 years. Depending on the wall orientation, optimum insulation thicknesses vary between 4.52 and 5.02 cm for heating, 1.56 and 2.09 cm for cooling, and 5.92 and 6.08 cm for annual energy requirements. The heating energy demands ranged from 54.8 MJ/m2 to 58.38 MJ/m2, while the cooling energy demands varied between 10.91 MJ/m2 and 12.08 MJ/m2, depending on the wall orientation. It has been concluded that the ideal insulation thicknesses for meeting cooling, heating, and annual energy demands vary depending on the wall orientation and the building’s use purpose.Keywords
This publication has 26 references indexed in Scilit:
- An integrated assessment of the financial and environmental impacts of exterior building insulation applicationJournal of Cleaner Production, 2023
- Influence of degree days calculation methods on the optimum thermal insulation thickness in life-cycle cost analysis for building envelopes in Mediterranean and Semi-Arid climatesJournal of Building Engineering, 2023
- Calculation of optimum insulation thickness of external walls in residential buildings by using exergetic life cycle cost assessment method: Case study for TurkeyEnvironmental Progress & Sustainable Energy, 2019
- The determination of the most economical combination between external wall and the optimum insulation material in Cameroonian's buildingsJournal of Building Engineering, 2017
- Determination of optimum insulation thickness for building walls by using heating and cooling degree-day values of all Turkey’s provincial centersEnergy and Buildings, 2016
- Determination of optimum insulation thickness based on cooling transmission load for building walls in a hot climateEnergy Conversion and Management, 2013
- A study on the optimum insulation thicknesses of various types of external walls with respect to different materials, fuels and climate zones in TurkeyApplied Energy, 2012
- Optimum insulation thicknesses for building walls with respect to cooling and heating degree-hours in the warmest zone of TurkeyBuilding and Environment, 2008
- Determination of optimum insulation thickness for building walls with respect to various fuels and climate zones in TurkeyApplied Thermal Engineering, 2006