High-Resolution Ultrasound-Guided High Interscalene Plexus Block for Carotid Endarterectomy
Authors:
- Thomas RoesselTRThomas Roessel
- Diana WiessnerDWDiana Wiessner
- Axel R. HellerAHAxel R. Heller
- Thomas ZimmermannTZThomas Zimmermann
- Thea KochTKThea Koch
- Rainer J. LitzRLRainer J. Litz
- 1 May 2007
- journal article
- Published by BMJ in Regional Anesthesia & Pain Medicine
- Vol. 32 (3) , 247-253
Abstract
High-resolution ultrasound imaging (HRUI) allows real-time visualization of peripheral nerves, needle insertion, and the spread of local-anesthetic (LA) solution. We evaluated the feasibility of performing a high interscalene brachial-plexus block for carotid endarterectomy by means of HRUI, thereby limiting the amount of LA to the dose required to sufficiently surround the relevant nerve structures. The interscalene brachial plexus was localized in the interscalene groove at its most cephalad point in 14 patients undergoing carotid endarterectomy by use of an ultrasound device with a 17.5 MHz transducer. Up to 20 mL of ropivacaine 0.5% was injected. In all patients, HRUI allowed clear delineation of the upper part of the interscalene brachial plexus at the level of the 4th cervical vertebra appearing as 1 hypoechoic, roundish, hypodense node located in a distance of 1.5 ± 0.3 cm to the skin, 1.5 ± 0.2 cm lateral to the common carotid artery, and 0.6 ± 0.2 cm from the transverse process of the spine. Likewise HRUI allowed a clear delineation of minor blood vessels and adjacent anatomic structures, as well as accurate placement of the needle close to the nerves. Real-time observation of LA spread during injection was possible, even in increments of less than 1 mL. High-resolution ultrasonic imaging allows clear depiction of the target tissues and facilitates accurate needle placement during high interscalene brachial-plexus blocks. This technique may minimize the risk of direct puncture-related complications, as well as accidental intravascular injection of LA. The observation of LA spread in all patients, even in small increments of less than 1 mL might enhance safety by limiting the injected LA to the actual demand. Well-placed LA spread could potentially avoid central nervous toxicity caused by intravascular injection or resorption of inadequately high dosages, in particular in nerve blocks of the highly vascularized neck region.Keywords
This publication has 16 references indexed in Scilit:
- Ultrasound-Guided Supraclavicular Brachial Plexus BlockAnesthesia & Analgesia, 2003
- Brachial Plexus Examination and Localization Using Ultrasound and Electrical StimulationAnesthesiology, 2003
- Brachial Plexus Sonography: A Technique for Assessing the Root LevelAmerican Journal of Roentgenology, 2002
- A Comparison of Two Techniques for Cervical Plexus Blockade: Evaluation of Efficacy and Systemic ToxicityAnesthesia & Analgesia, 1999
- Cranial Nerve X and XII Paralysis (Tapia's Syndrome) after an Interscalene Brachial Plexus Block for a Left Shoulder Mumford ProcedureAnesthesiology, 1999
- Anatomy of the normal brachial plexus revealed by sonography and the role of sonographic guidance in anesthesia of the brachial plexus.American Journal of Roentgenology, 1998
- Incidence and Clinical Significance of Hemidiaphragmatic Paresis in Patients Undergoing Carotid Endarterectomy During Cervical Plexus Block AnesthesiaJournal of Neurosurgical Anesthesiology, 1994
- Regional analgesia for carotid artery endarterectomy by winnie's single-injection technique using a nerve detectorJournal of Cardiothoracic and Vascular Anesthesia, 1992
- Hemidiaphragmatic Paresis During Interscalene Brachial Plexus BlockAnesthesia & Analgesia, 1992
- Peripheral nerves of the extremities: imaging with US.Radiology, 1988