A Comparison of Liquid Limit Values for Fine Soils: A Case Study at the North Cairo-Suez District, Egypt
- 1 March 2017
- journal article
- research article
- Published by Geological Society of India in Journal of the Geological Society of India
- Vol. 89 (3) , 339-343
Abstract
This study compare liquid limit values obtained by the Casagrande apparatus, Russian and British drop cone penetrometer. Liquid limit determined for clay samples collected from 10 boreholes at the Cairo-Suez district (north western part of Badr City), Egypt. It is the most important geotechnical parameter used of fine-grained soils. The liquid limits for 40 natural clay samples varying between 27.8 and 69.7%. It is found that the liquid limit determined by the Casagrande apparatus and Russian standard (cone penetrometer) give essentially the same results with a difference of < 5%. It is observed that the values of Casagrande apparatus were generally lower than those obtained by the cone penetrometer with Russian standard. In addition, Casagrande apparatus for some samples, which had liquid limits of more than 60%, give a higher result. The liquid limits determined by the Russian and British standards are not consistent with a difference of < 1%. Besides, the results which determined by the Casagrande apparatus and British standards (BS), provide equivalent values with a difference of < 3%.Keywords
This publication has 15 references indexed in Scilit:
- Comparison between Casagrande and drop-cone methods to calculate liquid limit for pure clayCanadian Journal of Soil Science, 2012
- Liquid limit of low- to medium-plasticity soils: comparison between Casagrande cup and cone penetrometer testBulletin of Engineering Geology and the Environment, 2011
- Comparison of liquid limit values determined using the hard and soft base Casagrande apparatus and the cone penetrometerBulletin of Engineering Geology and the Environment, 2009
- Quick and Reliable Procedure for Liquid Limit Determination of Fine-Grained SoilsGeotechnical Testing Journal, 2001
- Liquid limits and fall conesCanadian Geotechnical Journal, 1996
- A comparison of the Casagrande and fall cone penetrometer methods for liquid limit determination in marls from Crete, GreeceEngineering Geology, 1991
- The applicability of the cone penetrometer to determine the liquid limit of lateritic soilsGéotechnique, 1986
- Liquid Limit of Soil MixturesGeotechnical Testing Journal, 1985
- The Effect of Clay Content on Liquid Limit from a Fall Cone and the British Cup DeviceGeotechnical Testing Journal, 1985
- Notes on the Design of the Liquid Limit DeviceGéotechnique, 1958