Optimal Method for Catastrophic Faults Diagnosis in RC Ladder Network
Open Access
- 11 July 2016
- journal article
- research article
- Published by Wiley in Advances in Power Electronics
- Vol. 2016, 1-15
Abstract
The RC ladder network has been analyzed for various catastrophic fault detection using minimal number of measurements. Generally, electronic circuit testing procedure is very exhaustive and includes higher cost; the presented approach will save fault diagnosis time. It is not possible to analyze the big RC ladder network to give the good fault coverage, so the ladder network has been broken into segments of different sizes. However, if segment size is small, it will cause more area overhead compared to bigger step size in terms of the interconnections and pins on the integrated circuit. A systematic and detailed analysis for one-step, two-step, three-step, and four-step RC ladder networks has been carried out for various faults and optimal step size is proposed. It has been investigated that three measurements are optimal to localize different catastrophic faults in a RC ladder network.Keywords
This publication has 5 references indexed in Scilit:
- Fault detection in resistive ladder network with minimal measurementsMicroelectronics Reliability, 2012
- Diagnosis of Local Spot Defects in Analog CircuitsIEEE Transactions on Instrumentation and Measurement, 2012
- Entropy-Based Optimum Test Points Selection for Analog Fault Dictionary TechniquesIEEE Transactions on Instrumentation and Measurement, 2004
- Resistance and capacitance minimization in low-pass RC ladder networksIEEE Transactions on Circuits and Systems, 1975
- High-Q Resistance-Capacitance Ladder Phase-Shift NetworksIEEE Transactions on Circuit Theory, 1967