Measurement of cerebral oxygenation state in anaesthetized children using the INVOS 5100 cerebral oximeter
Authors:
- 5 June 2003
- journal article
- clinical trial
- Published by Wiley in Pediatric Anesthesia
- Vol. 13 (5) , 384-391
Abstract
Summary: Background: Near‐infrared spectroscopy is a developing technique for monitoring cerebral oxygenation during anaesthesia. The aim of this study was to evaluate absolute values of cerebral oxygenation during stable anaesthesia conditions in otherwise healthy children using the recently introduced INVOS 5100 cerebral oximeter with a paediatric and adult sensor and to compare them with values obtained from the NIRO 300 oximeter. Methods: Thirty paediatric surgical patients (aged 0.23–15.97 years) were studied during general anaesthesia with tracheal intubation and controlled ventilation. Comparative measurements of cerebral oxygenation were performed on the forehead with two probes within 10 min under stable cardiorespiratory and anaesthesia conditions. Cerebral oxygenation values (rSO2) obtained from the paediatric and adult INVOS 5100 sensors were compared with the tissue oxygenation index (TOI) obtained from the NIRO 300 cerebral oximeter using 4‐ and 5‐cm emitter‐detector separation. Results: Cerebral rSO2 values and the TOI values both showed a large range of cerebral oxygenation in the children studied (rSO2: 59–95%, TOI: 48–85%). Cerebral rSO2 values measured by the INVOS 5100, particularly with the paediatric sensor, were significantly higher than the TOI values obtained from the NIRO 300 (P < 0.0001). Agreement between the INVOS and NIRO oximeter was poor. Conclusion: The large range and the poor agreement of cerebral oxygenation values between the two oximeters makes it difficult to define a normal value. Cerebral oxygenation readings by these monitors, based on one single point measurement during anaesthesia, should be viewed with caution. Actually, there may be little indication for routine use of such monitoring during general anaesthesia.Keywords
This publication has 24 references indexed in Scilit:
- Bilaterales Monitoring der zerebralen Sauerstoffsättigung in der Aortenbogen-ChirurgieAINS - Anästhesiologie · Intensivmedizin · Notfallmedizin · Schmerztherapie, 2001
- Spatially resolved spectroscopy (NIRO-300) does not agree with jugular bulb oxygen saturation in patients undergoing warm bypass surgeryCanadian Journal of Anesthesia/Journal canadien d'anesthésie, 2001
- Comparison of two commercially available near-infrared spectroscopy instruments for cerebral oximetryJournal of Neurosurgery, 2000
- Regional low-flow perfusion provides cerebral circulatory support during neonatal aortic arch reconstructionThe Journal of Thoracic and Cardiovascular Surgery, 2000
- Noninvasive measurement of cerebral hemoglobin oxygen saturation using two near infrared spectroscopy approachesJournal of Biomedical Optics, 2000
- A comparison of the monitors INVOS 3100 and NIRO 500 in detecting changes in cerebral oxygenationActa Anaesthesiologica Scandinavica, 1999
- NEAR INFRARED SPECTROSCOPY DETECTS CRITICAL CEREBRAL HYPOXIA DURING CAROTID ENDARTERECTOMY IN AWAKE PATIENTSAnesthesiology, 1998
- Near-Infrared spectroscopy: Theory and applicationsJournal of Cardiothoracic and Vascular Anesthesia, 1996
- Optical pathlength measurements on adult head, calf and forearm and the head of the newborn infant using phase resolved optical spectroscopyPhysics in Medicine & Biology, 1995
- Intracerebral penetration of infrared lightJournal of Neurosurgery, 1992