Osteoconductivity of thermal-sprayed silver-containing hydroxyapatite coating in the rat tibia
- 1 May 2011
- journal article
- research article
- Published by British Editorial Society of Bone & Joint Surgery in The Journal of Bone and Joint Surgery. British volume
- Vol. 93-B (5) , 644-649
Abstract
A silver-containing hydroxyapatite (Ag-HA) coating has been developed using thermal spraying technology. We evaluated the osteoconductivity of this coating on titanium (Ti) implants in rat tibiae in relation to bacterial infection in joint replacement.At 12 weeks, the mean affinity indices of bone formation of a Ti, an HA, a 3%Ag-HA and a 50%Ag-HA coating were 97.3%, 84.9%, 81.0% and 40.5%, respectively. The mean affinity indices of bone contact of these four coatings were 18.8%, 83.7%, 77.2% and 40.5%, respectively. The indices of bone formation and bone contact around the implant of the 3%Ag-HA coating were similar to those of the HA coating, and no significant differences were found between them (bone formation, p = 0.99; bone contact, p = 0.957). However, inhibition of bone formation was observed with the 50%Ag-HA coating.These results indicate that the 3%Ag-HA coating has low toxicity and good osteoconductivity, and that the effect of silver toxicity on osteoconductivity depends on the dose.Keywords
This publication has 28 references indexed in Scilit:
- Silver Absorption on Burns After the Application of Acticoat™: Data From Pediatric Patients and a Porcine Burn ModelJournal of Burn Care & Research, 2009
- Development of novel thermal sprayed antibacterial coating and evaluation of release properties of silver ionsJournal of Biomedical Materials Research Part B: Applied Biomaterials, 2008
- Vancomycin Bound to Ti Rods Reduces Periprosthetic InfectionClinical Orthopaedics and Related Research, 2007
- The Influence of Elementary Silver Versus Titanium on Osteoblasts Behaviour In Vitro Using Human Osteosarcoma Cell LinesSarcoma, 2007
- Pathologic Analysis of 19 Heart Valves With Silver-Coated Sewing RingsJournal of Cardiac Surgery, 2006
- The effects of combined gentamicin–hydroxyapatite coating for cementless joint prostheses on the reduction of infection rates in a rabbit infection prophylaxis modelBiomaterials, 2006
- Ability of zirconia double coated with titanium and hydroxyapatite to bond to bone under load-bearing conditionsBiomaterials, 2006
- Histomorphometric and mechanical analysis of the hydroxyapatite-bone interface after electromagnetic stimulationThe Journal of Bone and Joint Surgery. British volume, 2006
- Inhibition of implant-associated infections via nitric oxide releaseBiomaterials, 2005
- Evaluation of metal implants coated with several types of ceramics as biomaterialsJournal of Biomedical Materials Research, 1989