Miri 4-Point Marker: An Innovative Tool for Flanged Intrascleral Intraocular Lens Fixation with Modified Yamane Technique

Authors:

Abstract
Background: Yamane’s flanged intrascleral intraocular lens (IOL) fixation is increasingly favored for eyes without capsular support. However, the conventional marking technique using Castroviejo calipers requires sequential point placement, which may compromise sclerotomy alignment and increase the risk of IOL tilt. A novel device, the Miri 4-point marker, has been developed to enable simultaneous, equidistant scleral marking, potentially improving precision and consistency. Despite the widespread adoption of the Yamane technique, comparative evidence on procedural refinements remains limited particularly in Malaysia, where no local data on modified techniques are available. Therefore, this study aimed to evaluate the clinical outcomes of the newly designed surgical tool, the Miri 4-Point marker in flanged intrascleral IOL fixation using the modified Yamane technique. Methods: This retrospective cohort study at a single hospital of Malaysia included 44 eyes operated on between 2024 and 2025. Conjunctival markings were made using either the Miri 4-Point marker or Castroviejo calipers. Two 30-gauge thin-walled needles created right-angled sclerotomies 2 mm posterior to the limbus. IOL haptics were externalized through the needles, cauterized to form a flange, and inserted into scleral tunnels. Descriptive statistics and binary logistic regression were used to assess factors associated with postoperative visual outcomes. Results: Among 44 patients (mean age 64.4 ± 9.7 years, 77.3% male) who underwent intrascleral IOL fixation, the Miri 4‑Point marker was used in 72.7% of cases. Outcomes with the Miri 4-point marker were comparable to Castroviejo calipers. Mean postoperative uncorrected visual acuity (UCVA) and best-corrected visual acuity (BCVA) were 0.7 ± 0.4 and 0.4 ± 0.3 logMAR, respectively. At one month postoperatively, 17.2% achieved good UCVA, increasing to 30.8% after excluding ocular comorbidities; 41.4% achieved good BCVA, rising to 46.2% without ocular comorbidities. On univariable analysis, high corneal astigmatism (> 2.5 D) was associated with poorer UCVA across all patients, regardless of Miri 4-Point marker use (OR = 0.07, 95% CI: 0.01, 0.78, p = 0.03). Multivariable analysis did not identify any independent predictors. Conclusions: The Miri 4‑point marker achieved non-inferior visual outcomes comparable to conventional methods, particularly in eyes without ocular comorbidities, while high corneal astigmatism was associated with poorer postoperative UCVA.

This publication has 21 references indexed in Scilit: