Electroanalytical Method for Quantification of Hepatocellular Carcinoma Cells as Charge Transport Barriers in Culture Media
- 16 January 2020
- journal article
- research article
- Published by Wiley in Electroanalysis
- Vol. 32 (5) , 890-897
Abstract
Here we report a strategy in which electroanalytical method was used to quantify human hepatic carcinoma cell (HepG2) density in culture media and their interaction with biomolecules. The cyclic voltammogram response of vitamin and amino acids redox mediators containing culture media had shown distinct oxidation peak at −0.63 V along with a low intensity peak at +0.67 V. Both oxidation and reduction peak current of culture media were gradually decreased with an increase in cell number indicating their role as charge transport barrier at electrode surface. The difference between cathodic and anodic peak potential was also decreased with the addition of cells. The oxidation peak disappeared in CV response, with the addition of optimum cell number in culture media, indicating the adsorption of redox mediators at cell surface. CV response of fetal bovine serum (FBS) containing cell suspension showed presence of reduction and oxidation peaks of culture media in CV. This indicates stronger possibility of binding of serum proteins with cells and release of redox mediators in culture media. The chemical interactions of cells with FBS was further confirmed by the FTIR and UV‐Vis spectroscopy. The viability, adhesion and proliferation responses of the cells were found to be normal. The reported electroanalytical method may be applied in the future for rapid quantification of cell density and confirmation of interactions among cells and biomolecules.Keywords
This publication has 50 references indexed in Scilit:
- Changes in Electric Properties of Human Breast Cancer CellsThe Journal of Membrane Biology, 2012
- Regulation of cancer cell metabolismNature Reviews Cancer, 2011
- Effects of nanopatterned RGD peptide layer on electrochemical detection of neural cell chipBiosensors and Bioelectronics, 2010
- Electrochemical studies of novel chitosan/TiO2 bioactive electrode for biosensing applicationElectrochemistry Communications, 2008
- Electrochemical impedance measurement of prostate cancer cells using carbon nanotube array electrodes in a microfluidic channelNanotechnology, 2007
- Immobilization and electrochemical behavior of gold nanoparticles modified leukemia K562 cells and application in drug sensitivity testElectrochemistry Communications, 2007
- Real time monitoring of drug metabolic enzyme response inside human hepatoma GS-3A4-HepG2 cells by means of electrochemical impedance measurementPolymers for Advanced Technologies, 2004
- On-Line Monitoring of Cell Growth and Cytotoxicity Using Electric Cell-Substrate Impedance Sensing (ECIS)Biotechnology Progress, 2003
- Electrochemical Monitoring of Anticancer Compounds on the Human Ovarian Carcinoma Cell Line A2780 and Its Adriamycin- and Cisplatin-Resistant VariantsExperimental Cell Research, 2002
- pH Changes in Pulsed CO2 Incubators Cause Periodic Changes in Cell MorphologyExperimental Cell Research, 1994