How Slow Can We Go? 4 Frames Per Second (fps) Versus 7.5 fps Fluoroscopy for Atrial Septal Defects (ASDs) Device Closure
- 25 January 2015
- journal article
- Published by Springer Nature in Pediatric Cardiology
- Vol. 36 (5) , 1057-1061
Abstract
Radiation exposure remains a significant concern for ASD device closure. In an effort to reduce radiation exposure, the default fluoroscopy frame rate in our Siemens biplane pediatric catheterization laboratory was reduced to 4 fps in November 2013 from an earlier 7.5 fps fluoro rate. This study aims to evaluate the components contributing to total radiation exposure and compare the procedural success and radiation exposure during ASD device closure using 4 versus 7.5 fps fluoroscopy rates. Twenty ASD device closures performed using 4 fps fluoro rate were weight-matched to 20 ASD closure procedures using 7.5 fps fluoro rate. Baseline characteristics, procedure times and case times were similar in the two groups. Device closure was successful in all but one case in the 4 fps group. The dose area product (DAP), normalized DAP to body weight, total radiation time and fluoro time were lower in the 4 fps group but not statistically different than the 7.5 fps. The number of cine images and cine times were identical in both groups. Fluoroscopy and cineangiography contributed equally to radiation exposure. Fluoroscopy at 4 fps can be safe and effective for ASD device closure in children and adults. There was no increase in procedure time, cine time, fluoro time or complications at this slow fluoro rate. There was a trend toward decreased radiation exposure as measured by indexed DAP although not statistically significant in this small study. Further study with multiple operators using 4 fps fluoroscopy for simple interventional procedures is recommended.Keywords
This publication has 12 references indexed in Scilit:
- Measures to Reduce Radiation in a Modern Cardiac Catheterization LaboratoryCirculation: Cardiovascular Interventions, 2014
- Patient Radiation Exposure in a Modern, Large-Volume, Pediatric Cardiac Catheterization LaboratoryPediatric Cardiology, 2014
- 2012 American College of Cardiology Foundation/Society for Cardiovascular Angiography and Interventions Expert Consensus Document on Cardiac Catheterization Laboratory Standards UpdateJACC, 2012
- Characterization of radiation exposure and effect of a radiation monitoring policy in a large volume pediatric cardiac catheterization labCatheterization and Cardiovascular Interventions, 2011
- Radiation Dose to the Pediatric Cardiac Catheterization and Intervention PatientAmerican Journal of Roentgenology, 2010
- Community Use of the Amplatzer Atrial Septal Defect Occluder: Results of the Multicenter MAGIC Atrial Septal Defect StudyPediatric Cardiology, 2008
- Radiation Risk to Children From Computed TomographyPediatrics, 2007
- The ALARA concept in pediatric cardiac catheterization: techniques and tactics for managing radiation dosePediatric Radiology, 2006
- Cardiac catheterization and long-term chromosomal damage in children with congenital heart diseaseEuropean Heart Journal, 2006
- Comparison of results and complications of surgical and amplatzer device closure of atrial septal defectsThe Journal of Thoracic and Cardiovascular Surgery, 1999