Hydrogen embrittlement is a serious problem for high strength steels because the susceptibility increases with the strength of steels. Reducing hydrogen absorption into steels is required for the prevention of hydrogen embrittlement. It is well-known that one of the hydrogen absorption processes for steels is atmospheric corrosion. In general, atmospheric corrosion causes a rough and non-uniform surface, thus hydrogen absorption into steels during the corrosion process is thought to have an uneven distribution. To observe the distribution of hydrogen absorption into steels, we reported a method for hydrogen mapping using a WO3 thin film1,2). As hydrogen enters, the WO3 film formed on the hydrogen-detection side changes color by the reaction from WO3 to HxWO3. In this study, the hydrogen mapping method was improved and became more responsive and visible using Mn oxide instead of WO3. In addition, we succeeded in visualizing the distribution of hydrogen absorption into the high strength steel during the corrosion process in 0.01 M NaCl using the hydrogen mapping method with Mn oxide. The hydrogen mapping test shows that the areas where the color of Mn oxide changed corresponded to the areas where corrosion products were deposited on the hydrogen-entry side. This result suggests that hydrogen absorption into the steel occurred at the corroded areas and did not occur preferentially at the cathodic reaction site. 1) Y. Sugawara, Y. Sakaizawa, A. Shibata, I. Muto, N. Hara, ISIJ Int., 58, 1860 (2018). 2) Y. Sugawara, H. Saito, ISIJ Int., 61, 1201 (2021).