Improving the performance of culture‐based bacterial screening by increasing the sample volume from 4 mL to 8 mL in aerobic culture bottles
Authors:
- 29 December 2011
- journal article
- research article
- Published by Wiley in Transfusion
- Vol. 52 (7) , 1576-1582
Abstract
BACKGROUND: In the setting of bacterial detection of apheresis platelets (PLTs), the manufacturer recommended PLT inoculation volume for BacT/ALERT culture bottles (bioMérieux) ranges from 4 to 10 mL. This study compares the rate of capture of true‐positive (TP) contaminations between aerobic culture bottles inoculated with either 4 or 8 mL of sample and assesses if a larger sample volume reduces time to detection.STUDY DESIGN AND METHODS: Detection of TP samples and mean time to detection were compared for 4‐ and 8‐mL samples collected between September 1, 2003, and May 2, 2011.RESULTS: A total of 180,263 and 283,114 PLT collections were tested with an 8‐ and 4‐mL sample, respectively. Analysis of TP rates by volume sampled show an increase in the rate of detection of TP with the 8‐mL sample relative to the 4‐mL sample (139 vs. 106 per million events; odds ratio, 1.31; 95% confidence interval, 0.77‐2.23). Comparison of mean time to detection for TP shows a decrease in mean time to detection using 8 mL compared with 4 mL (12.36 ± 3.7 hr to 15.97 ± 6.3 hr, p = 0.012).CONCLUSION: Doubling the sample volume to 8 mL showed a trend in improvement for the rate of detection of TP and shortened the mean time of detection for TP by 23% when compared to a sample volume of 4 mL. The decrease in mean time to detection using a larger sample volume suggests that a shorter release time after inoculation could be achieved without significantly increasing patient risk.Keywords
This publication has 12 references indexed in Scilit:
- Screening of platelets for bacterial contamination at the Welsh Blood ServiceTransfusion Medicine, 2010
- BLOOD COMPONENTS: Screening of single‐donor apheresis platelets for bacterial contamination: the PASSPORT study resultsTransfusion, 2010
- Bacterial contamination of plateletsTransfusion and Apheresis Science, 2010
- Frequency of bacterial contamination of platelet concentrates before and after introduction of diversion method in JapanTransfusion, 2009
- Limiting and detecting bacterial contamination of apheresis platelets: inlet‐line diversion and increased culture volume improve component safetyTransfusion, 2009
- The impact of discontinuation of 7-day storage of apheresis platelets (PASSPORT) on recipient safety: an illustration of the need for proper risk assessmentsTransfusion, 2009
- Bacterial detection in apheresis platelets: blood systems experience with a two-bottle and one-bottle culture systemTransfusion, 2008
- Relationship between Bacterial Load, Species Virulence, and Transfusion Reaction with Transfusion of Bacterially Contaminated PlateletsClinical Infectious Diseases, 2008
- A model to predict the improvement of automated blood culture bacterial detection by doubling platelet sample volumeTransfusion, 2007
- Effects of skin disinfection method, deviation bag, and bacterial screening on clinical safety of platelet transfusions in the NetherlandsTransfusion, 2006