Accuracy, User Acceptability, and Safety Evaluation for the FreeStyle Libre Flash Glucose Monitoring System When Used by Pregnant Women with Diabetes
Open Access
- 1 March 2018
- journal article
- research article
- Published by SAGE Publications in Diabetes Technology & Therapeutics
- Vol. 20 (3) , 180-188
Abstract
Background: Accuracy of the FreeStyle Libre™ Flash Glucose Monitoring System has not been evaluated in pregnant women with diabetes. The aim of this study was to determine accuracy (compared to self-monitoring of blood glucose [SMBG]), clinical safety, and acceptability of the FreeStyle Libre System when used at home by this population. Materials and Methods: Seventy-four participants, with type 1 (T1D, n = 24), type 2 (T2D, n = 11), or gestational (n = 39) diabetes, were enrolled across 13 sites (9 in United Kingdom, 4 in Austria). Average gestation was 26.6 ± 6.8 weeks (mean ± standard deviation), age was 30.5 ± 5.1 years, diabetes duration was 13.1 ± 7.3 years for T1D and 3.2 ± 2.5 years for T2D, and 49/74 (66.2%) used insulin to manage their diabetes. Sensors were worn for up to 14 days. Sensor glucose values (masked) were compared with capillary SMBG values (made at least 4 times/day). Results: Clinical accuracy of sensor results versus SMBG results was demonstrated, with 88.1% and 99.8% of results within Zone A and Zones A and B of the Consensus Error Grid, respectively. Overall mean absolute relative difference was 11.8%. Sensor accuracy was unaffected by the type of diabetes, the stage of pregnancy, whether insulin was used, age or body mass index. User questionnaires indicated high levels of satisfaction with sensor wear, system use, and comparison to SMBG. There were no unanticipated device-related adverse events. Conclusions: Good agreement was demonstrated between the FreeStyle Libre System and SMBG. Accuracy of the system was unaffected by patient characteristics, indicating that the system is safe and accurate to use by pregnant women with diabetes.Keywords
This publication has 30 references indexed in Scilit:
- Hypoglycaemia during pregnancy in women with Type 1 diabetesDiabetic Medicine, 2012
- A Randomized Clinical Trial to Assess the Efficacy and Safety of Real-Time Continuous Glucose Monitoring in the Management of Type 1 Diabetes in Young Children Aged 4 to <10 YearsDiabetes Care, 2012
- Patient satisfaction and barriers to initiating real‐time continuous glucose monitoring in early pregnancy in women with diabetesDiabetic Medicine, 2011
- Closed-Loop Insulin Delivery During Pregnancy Complicated by Type 1 DiabetesDiabetes Care, 2011
- Effectiveness of Continuous Glucose Monitoring in a Clinical Care EnvironmentDiabetes Care, 2009
- Peri-Conceptional A1C and Risk of Serious Adverse Pregnancy Outcome in 933 Women With Type 1 DiabetesDiabetes Care, 2009
- Continuous Glucose Monitoring and Intensive Treatment of Type 1 DiabetesNew England Journal of Medicine, 2008
- Effectiveness of continuous glucose monitoring in pregnant women with diabetes: randomised clinical trialBMJ, 2008
- Managing Preexisting Diabetes for PregnancyDiabetes Care, 2008
- Hypoglycemia in Pregnant Women With Type 1 DiabetesDiabetes Care, 2008