Communication of mechanically ventilated patients in intensive care units
Open Access
- 1 January 2016
- journal article
- Published by Associação de Medicina Intensiva Brasileira in Revista Brasileira de Terapia Intensiva
- Vol. 28 (2) , 132-40
Abstract
The aim of this study was to translate and culturally and linguistically adapt the Ease of Communication Scale and to assess the level of communication difficulties for patients undergoing mechanical ventilation with orotracheal intubation, relating these difficulties to clinical and sociodemographic variables. This study had three stages: (1) cultural and linguistic adaptation of the Ease of Communication Scale; (2) preliminary assessment of its psychometric properties; and (3) observational, descriptive-correlational and cross-sectional study, conducted from March to August 2015, based on the Ease of Communication Scale - after extubation answers and clinical and sociodemographic variables of 31 adult patients who were extubated, clinically stable and admitted to five Portuguese intensive care units. Expert analysis showed high agreement on content (100%) and relevance (75%). The pretest scores showed a high acceptability regarding the completion of the instrument and its usefulness. The Ease of Communication Scale showed excellent internal consistency (0.951 Cronbach's alpha). The factor analysis explained approximately 81% of the total variance with two scale components. On average, the patients considered the communication experiences during intubation to be "quite hard" (2.99). No significant correlation was observed between the communication difficulties reported and the studied sociodemographic and clinical variables, except for the clinical variable "number of hours after extubation" (p < 0.05). This study translated and adapted the first assessment instrument of communication difficulties for mechanically ventilated patients in intensive care units into European Portuguese. The preliminary scale validation suggested high reliability. Patients undergoing mechanical ventilation reported that communication during intubation was "quite hard", and these communication difficulties apparently existed regardless of the presence of other clinical and/or sociodemographic variables.Keywords
This publication has 29 references indexed in Scilit:
- The number of mechanically ventilated ICU patients meeting communication criteriaHeart & Lung, 2015
- Determining the effectiveness of illustrated communication material for communication with intubated patients at an intensive care unitInternational Journal of Nursing Practice, 2013
- Clinical Practice Guidelines for the Management of Pain, Agitation, and Delirium in Adult Patients in the Intensive Care UnitCritical Care Medicine, 2013
- The lived experiences of adult intensive care patients who were conscious during mechanical ventilation: A phenomenological-hermeneutic studyIntensive and Critical Care Nursing, 2012
- Promoting Effective Communication for Patients Receiving Mechanical VentilationCritical Care Nurse, 2011
- Improving Patient-Provider CommunicationJONA: The Journal of Nursing Administration, 2009
- Use of the quasi-experimental sequential cohort design in the Study of Patient–Nurse Effectiveness with Assisted Communication Strategies (SPEACS)Contemporary Clinical Trials, 2008
- Stressful experiences in relation to depth of sedation in mechanically ventilated patientsNursing in Critical Care, 2007
- Delirium as detected by the CAM-ICU predicts restraint use among mechanically ventilated medical patients*Critical Care Medicine, 2005
- Patients’ reports of health care practitioner interventions that are related to communication during mechanical ventilationHeart & Lung, 2004