Effective application of the methanol‐based PreservCyt™ fixative and the Cellient™ automated cell block processor to diagnostic cytopathology, immunocytochemistry, and molecular biology
- 27 February 2013
- journal article
- molecular cytopathology
- Published by Wiley in Diagnostic Cytopathology
- Vol. 41 (8) , 734-741
Abstract
We studied the feasibility of immunocytochemistry (ICC), in situ hybridization (ISH), and polymerase chain reaction (PCR) after Cellient™ automated cell block processing, and tested whether methanol‐based PreservCyt™ fixation could replace formalin fixation, in an attempt to eliminate toxic formaldehyde vapors. Immunostaining with 30 different antibodies was performed on cell blocks from 73 FNA specimens and 42 body cavity fluid specimens prepared by Cellient™ automated processing that uses the methanol‐based fixative (PreservCyt™). For each antibody we evaluated ICC in at least three different cell block specimens and compared it with immunohistochemistry (IHC) in formalin‐fixed, paraffin‐embedded (FFPE) histological sections from the corresponding tumors. The quality of DNA and RNA in Cellient™ blocks was analyzed by ISH, applying a SYT gene break‐apart assay and EBER probes, respectively. Moreover, DNA quality was analyzed by PCR by using primer sets for DNA products of 100, 200, 300, 400, 500, and 600 base pairs, and evaluated by gel electrophoresis. When compared with IHC results in corresponding FFPE tumor tissue from the same patient, 24 out of 30 antibodies showed concordant ICC results. With FISH, distinctive hybridization signals were observed for SYT DNA sequences and EB virus RNA sequences. With PCR, DNA products, up to 600 base pairs in size, were readily observed after gel electrophoresis. The antibodies that showed concordant immunostaining in Cellient™ blocks could be applied to diagnostic algorithms that proved to be helpful in the discrimination of major tumor types (carcinoma, lymphoma, melanoma, and germ cell tumors), discrimination of carcinoma subtypes, and determination of primary tumor site in cases of metastatic carcinoma. In a separate study, we found that the application of ICC to this cell block technique provided additional diagnostic and clinically important information in 24% of 100 consecutive cases. The high quality of DNA and RNA in Cellient™ cell blocks allowed sensitive and specific molecular biologic analysis, in particular FISH and PCR. Diagn. Cytopathol. 2013;41:734–741.Keywords
This publication has 9 references indexed in Scilit:
- Comparison of Breast Carcinoma Prognostic/Predictive Biomarkers on Cell Blocks Obtained by Various Methods: Cellient, Formalin and ThrombinActa Cytologica, 2012
- External quality control for immunocytochemistry on cytology samples: a review of UK NEQAS ICC (cytology module) resultsCytopathology, 2011
- Cellient™ automated cell block versus traditional cell block preparation: A comparison of morphologic features and immunohistochemical stainingDiagnostic Cytopathology, 2010
- Sox10: A Pan-Schwannian and Melanocytic MarkerAmerican Journal of Surgical Pathology, 2008
- Diagnostic Accuracy of FISH and RT-PCR in 50 Routinely Processed Synovial SarcomasApplied Immunohistochemistry & Molecular Morphology, 2008
- Design and standardization of PCR primers and protocols for detection of clonal immunoglobulin and T-cell receptor gene recombinations in suspect lymphoproliferations: Report of the BIOMED-2 Concerted Action BMH4-CT98-3936Leukemia, 2003
- Comparison of three commonly used cytologic preparations in effusion immunocytochemistryDiagnostic Cytopathology, 2002
- AgarCyto: A Novel Cell-processing Method for Multiple Molecular Diagnostic Analyses of the Uterine CervixJournal of Histochemistry & Cytochemistry, 2000
- A review of 50 consecutive cytology cell block preparations in a large general hospital.Journal of Clinical Pathology, 1997