Collateral Function in Chronic Total Coronary Occlusions Is Related to Regional Myocardial Function and Duration of Occlusion
- 4 December 2001
- journal article
- other
- Published by Wolters Kluwer Health in Circulation
- Vol. 104 (23) , 2784-2790
Abstract
Background Collateral circulation can maintain myocardial function and viability in chronic total coronary occlusion (TCO). The present study evaluates the relation of myocardial function and duration of occlusion to collateral function. Methods and Results A total of 50 patients underwent a successful recanalization of a TCO (>4 weeks’ duration). Collateral function was assessed by intracoronary Doppler and pressure recordings before the first balloon inflation and after PTCA had been completed. Collateral function was assessed by Doppler- (CFI D ) and pressure-derived collateral flow indices (CFI P ), as well as indices of collateral (R Coll ) and peripheral resistance (R P ). Patients with normokinesia had lower R Coll (4.9±2.5 versus 11.8±8.2 mm Hg · cm −1 · s −1 ; P =0.033) and lower R P (3.8±1.9 versus 6.1±4.1 mm Hg · cm −1 · s −1 ; P =0.031) than those with akinesia. Patients with akinesia and a TCO duration of ≤3 months had the highest R Coll and R P , whereas those with akinesia and a longer TCO duration had similar collateral function as patients with normokinesia. After PTCA, CFI D and CFI P decreased from 0.37±0.20 to 0.21±0.17 ( P P Coll of 139±128% ( P P by 65±99% ( P =0.003). This attenuation of collateral function was less pronounced with epicardial collaterals than with intramyocardial collaterals. Conclusions Collateral function was better in patients with TCO and normal regional function than in those with impaired regional function. In the latter group, collateral function improvement was time dependent. After recanalization, the recruitable collateral function was attenuated because of an increase of R Coll and R P .Keywords
This publication has 19 references indexed in Scilit:
- Differential characterization of human coronary collateral blood flow velocityAmerican Heart Journal, 1996
- Relation between collateral flow assessed by Doppler guide wire and angiographic collateral gradesAmerican Heart Journal, 1995
- Collateral flow velocity alterations in the supply and receiving coronary arteries during angioplasty for total coronary occlusionCatheterization and Cardiovascular Diagnosis, 1995
- Relation between changes in blood flow of the contralateral coronary artery and the angiographic extent and function of recruitable collateral vessels arising from this artery during balloon coronary occlusionJACC, 1994
- Instantaneous recruitment of reversed coronary collaterals that had been dormant for six yearsCatheterization and Cardiovascular Diagnosis, 1992
- Detection of coronary collateral flow by a Doppler-tipped guide wire during coronary angioplastyAmerican Heart Journal, 1991
- Microvascular and collateral adaptation in swine hearts following progressive coronary artery stenosisBasic Research in Cardiology, 1989
- The collateral circulation of the heartProgress in Cardiovascular Diseases, 1988
- The resolution of coronary collaterals after successful percutaneous transluminal coronary angioplastyAmerican Heart Journal, 1988
- Changes in collateral channel filling immediately after controlled coronary artery occlusion by an angioplasty balloon in human subjectsJACC, 1985