Association between integrated backscatter and arrhythmia in patients with ischemic dilated cardiomyopathy
- 10 May 2021
- journal article
- research article
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 44 (6) , 1010-1017
Abstract
Background: Ventricular scars due to myocardial infarction provide a substrate for ventricular arrhythmias, and cardiac magnetic resonance (CMR) is the golden standard for the quantification of scar tissue magnitude. CMR has still limitations with patients with ICD despite ICD's becoming MR‐compatible. We investigated the association between calibrated integrated backscatter (cIBS) and arrhythmia frequency in patients with ICD.Methods: Thirty‐two ischemic dilated cardiomyopathy (ICM) patients with VVI‐ICD (mean age 66.56 ± 9.05, 28 male, and four female) were divided into three groups according to their arrhythmia frequency (ventricular arrhythmia—[VA ‐], VA + [VA +], and arrhythmia storm [AS]). Then with transthoracic echocardiography (TTE), all patients’ cIBS values were calculated and these values were compared with the patients’ arrhythmia frequency.Results: cIBS values of patients with VA + and AS were significantly higher in the apical‐septal (0.66 ± 0.11 vs. 0.50 ± 0.16, p = .008) and apical‐lateral (0.62 ± 0.19 vs. 0.46 ± 0.18, p = .041) segments compared to those of patients with VA ‐. The cIBS values of apical‐septal (0.50 ± 0.16 vs. 0.65 ± 0.08 vs. 0.66 ± 0.13 respectively, p = .032) and apical‐anterior (0.53 ± 0.22 vs. 0.48 ± 0.17 vs. 0.79 ± 0.23 respectively, p = .03) segments were significantly different between the groups. Furthermore, in the post hoc analysis, the difference was significantly higher in VA + than VA ‐ in the apical‐septal segment and higher in AS than VA + in apical‐anterior segments.Conclusion: Our findings suggest an association between the cIBS values and arrhythmia frequency in the study group.Keywords
This publication has 29 references indexed in Scilit:
- Feasibility of Cardiac Magnetic Resonance Wideband Protocol in Patients With Implantable Cardioverter Defibrillators and Its Utility for Defining ScarThe American Journal of Cardiology, 2019
- Impact of ICD Artifact Burden on Late Gadolinium Enhancement Cardiac MR Imaging in Patients Undergoing Ventricular Tachycardia AblationPacing and Clinical Electrophysiology, 2014
- Relationship between ultrasonic tissue characterization and myocardial deformation for prediction of left ventricular reverse remodelling in non-ischaemic dilated cardiomyopathy.European Heart Journal - Cardiovascular Imaging, 2011
- Prediction of Cardiac Resynchronization Therapy ResponseCirculation: Cardiovascular Imaging, 2010
- Integrated backscatter for the assessment of myocardial viabilityCurrent Opinion in Cardiology, 2006
- Use of echocardiography for predicting myocardial viability in patients with reperfused anterior wall myocardial infarctionThe American Journal of Cardiology, 2000
- Myocardial tissue characterization in heart failure by real-time integrated backscatterEuropean Journal of Ultrasound, 1999
- In vivo quantitative ultrasonic evaluation of myocardial fibrosis in humans.Circulation, 1990
- In vivo radiofrequency ultrasound analysis of normal human heart structuresJournal of Clinical Ultrasound, 1987
- Changes in myocardial backscatter throughout the cardiac cycleUltrasonic Imaging, 1983