Multi-objective Phasor Measurement Unit Placement in Electric Power Networks: Integer Linear Programming Formulation
Authors:
- 25 August 2015
- journal article
- research article
- Published by Taylor & Francis in Electric Power Components and Systems
- Vol. 43 (17) , 1902-1911
Abstract
A multi-objective optimal phasor measurement unit placement model using integer linear programming is presented in this article. The proposed model simultaneously optimizes two objectives, i.e., minimization of phasor measurement unit numbers and maximization of measurement redundancy. To calculate the redundancy criteria, the single-line outage and the phasor measurement unit loss are considered simultaneously. A linear formulation is presented for both objective functions. Also herein, to address conflicting attributes and identify Pareto optimal solutions of the multi-objective optimal phasor measurement unit placement problem, a new multi-objective mathematical programming method is proposed. Finally, a new index, i.e., minimum distance to utopia point, is implemented to select the most preferred solution among the available Pareto front based options on the goal to achieve judicious decision makers. Two test systems, i.e., a modified 9-bus and an IEEE 118-bus test systems, are used to illustrate the effectiveness of the proposed framework.Keywords
This publication has 27 references indexed in Scilit:
- Participation factor approach for phasor measurement unit placement in power system state estimationIET Generation, Transmission & Distribution, 2012
- State estimation and observability analysis for phasor measurement unit measured systemsIET Generation, Transmission & Distribution, 2012
- Multi-objective electricity market clearing considering dynamic security by lexicographic optimization and augmented epsilon constraint methodApplied Soft Computing, 2011
- Multi-criteria decision-making approach for multi-stage optimal placement of phasor measurement unitsIET Generation, Transmission & Distribution, 2011
- Reliability Analysis of Phasor Measurement Unit Using Hierarchical Markov ModelingElectric Power Components and Systems, 2009
- Placement of PMUs to Enable Bad Data Detection in State EstimationIEEE Transactions on Power Systems, 2006
- Optimal meter placement using genetic algorithm to maintain network observabilityExpert Systems with Applications, 2006
- Evenly Distributed Pareto Points in Multi-Objective Optimal Power FlowIEEE Transactions on Power Systems, 2006
- Phasor Measurement Unit Placement Techniques for Complete and Incomplete ObservabilityIEEE Transactions on Power Delivery, 2005
- Nondominated sorting genetic algorithm for optimal phasor measurement placementIEEE Transactions on Power Systems, 2003