Multi-objective Parameter Auto-tuning for Tissue Image Segmentation Workflows
Open Access
- 6 November 2018
- journal article
- research article
- Published by Springer Nature in Journal of Digital Imaging
- Vol. 32 (3) , 521-533
Abstract
We propose a software platform that integrates methods and tools for multi-objective parameter auto-tuning in tissue image segmentation workflows. The goal of our work is to provide an approach for improving the accuracy of nucleus/cell segmentation pipelines by tuning their input parameters. The shape, size, and texture features of nuclei in tissue are important biomarkers for disease prognosis, and accurate computation of these features depends on accurate delineation of boundaries of nuclei. Input parameters in many nucleus segmentation workflows affect segmentation accuracy and have to be tuned for optimal performance. This is a time-consuming and computationally expensive process; automating this step facilitates more robust image segmentation workflows and enables more efficient application of image analysis in large image datasets. Our software platform adjusts the parameters of a nuclear segmentation algorithm to maximize the quality of image segmentation results while minimizing the execution time. It implements several optimization methods to search the parameter space efficiently. In addition, the methodology is developed to execute on high-performance computing systems to reduce the execution time of the parameter tuning phase. These capabilities are packaged in a Docker container for easy deployment and can be used through a friendly interface extension in 3D Slicer. Our results using three real-world image segmentation workflows demonstrate that the proposed solution is able to (1) search a small fraction (about 100 points) of the parameter space, which contains billions to trillions of points, and improve the quality of segmentation output by × 1.20, × 1.29, and × 1.29, on average; (2) decrease the execution time of a segmentation workflow by up to 11.79× while improving output quality; and (3) effectively use parallel systems to accelerate parameter tuning and segmentation phases.Keywords
Funding Information
- National Cancer Institute (1U24CA180924-01A1)
- U.S. National Library of Medicine (R01LM009239, R01LM011119-01)
- National Institutes of Health (K25CA181503)
- Conselho Nacional de Desenvolvimento Científico e Tecnológico
This publication has 60 references indexed in Scilit:
- Approaches to automatic parameter fitting in a microscopy image segmentation pipeline: An exploratory parameter space analysisJournal of Pathology Informatics, 2013
- Validation of Interobserver Agreement in Lung Cancer Assessment: Hematoxylin-Eosin Diagnostic Reproducibility for Non–Small Cell Lung Cancer: The 2004 World Health Organization Classification and Therapeutically Relevant SubsetsArchives of Pathology & Laboratory Medicine, 2013
- Quantitative comparison of immunohistochemical staining measured by digital image analysis versus pathologist visual scoringDiagnostic Pathology, 2012
- Integrated morphologic analysis for the identification and characterization of disease subtypesJournal of the American Medical Informatics Association, 2012
- Intra- and inter-observer variability in measurement of target lesions: implication on response evaluation according to RECIST 1.1Radiology and Oncology, 2012
- Interobserver Variability in Histologic Evaluation of Radical Prostatectomy Between Central and Local Pathologists: Findings of TAX 3501 Multinational Clinical TrialUrology, 2011
- Expert second-opinion pathology review of lymphoma in the era of the World Health Organization classificationAnnals of Oncology, 2011
- Computer-aided prognosis of neuroblastoma on whole-slide images: Classification of stromal developmentPattern Recognition, 2009
- Interobserver reproducibility of Gleason grading of prostatic carcinoma: General pathologistHuman Pathology, 2001
- Factorial Sampling Plans for Preliminary Computational ExperimentsTechnometrics, 1991