Use of a novel two‐dimensional ionization chamber array for pencil beam scanning proton therapy beam quality assurance
Open Access
- 8 May 2015
- journal article
- research article
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 16 (3) , 270-276
Abstract
The need to accurately and efficiently verify both output and dose profiles creates significant challenges in quality assurance of pencil beam scanning (PBS) proton delivery. A system for PBS QA has been developed that combines a new two-dimensional ionization chamber array in a waterproof housing that is scanned in a water phantom. The MatriXX PT has the same detector array arrangement as the standard but utilizes a smaller 2 mm plate spacing instead of 5 mm. Because the bias voltage of the MatriXX PT and Evolution cannot be changed, PPC40 and FC65-G ionization chambers were used to assess recombination effects. The PPC40 is a parallel plate chamber with an electrode spacing of 2 mm, while the FC65-G is a Farmer chamber FC65-G with an electrode spacing of 2.8 mm. Three bias voltages (500, 200, and 100 V) were used for both detectors to determine which radiation type (continuous, pulse or pulse-scanned beam) could closely estimate from the ratios of charges collected. In comparison with the , a significant improvement in measurement of absolute dose with the MatriXX PT was observed. While dose uncertainty of the can be up to 4%, it is for the MatriXX PT. Therefore the should not be used for QA of PBS for conditions in which ion recombination is not negligible. Farmer chambers should be used with caution for measuring the absolute dose of PBS beams, as the uncertainty of can be ; chambers with an electrode spacing of 2 mm or smaller are recommended. PACS number: 87.53.Qc
Keywords
This publication has 18 references indexed in Scilit:
- Experimental characterization of two-dimensional spot profiles for two proton pencil beam scanning nozzlesPhysics in Medicine & Biology, 2013
- Commissioning dose computation models for spot scanning proton beams in water for a commercially available treatment planning systemMedical Physics, 2013
- Golden beam data for proton pencil-beam scanningPhysics in Medicine & Biology, 2012
- Verification of patient‐specific dose distributions in proton therapy using a commercial two‐dimensional ion chamber arrayMedical Physics, 2010
- Use of a two‐dimensional ionization chamber array for proton therapy beam quality assuranceMedical Physics, 2008
- Multichannel detectors for profile measurements in clinical proton fieldsMedical Physics, 2007
- Experimental characterization and physical modelling of the dose distribution of scanned proton pencil beamsPhysics in Medicine & Biology, 2005
- Treatment planning and verification of proton therapy using spot scanning: Initial experiencesMedical Physics, 2004
- The recombination correction for an ionisation chamber exposed to pulsed radiation in a 'swept beam' technique. I. TheoryPhysics in Medicine & Biology, 1982
- Current collection and ionic recombination in small cylindrical ionization chambers exposed to pulsed radiationBritish Journal of Radiology, 1980