Finite element analysis of the contact interface between trans-femoral stump and prosthetic socket
- 1 July 2013
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2013 (1094687X) , 1270-1273
Abstract
Transfemoral amputees need prosthetic devices after amputation surgery, and the interface pressure between the residual limb and prosthetic socket has a significant effect on an amputee's satisfaction and comfort. The purpose of this study was to build a nonlinear finite element model to investigate the interface pressure between the above-knee residual limb and its prosthetic socket. The model was three-dimensional (3D) with consideration of nonlinear boundary conditions. Contact analysis was used to simulate the friction conditions between skin and the socket. The normal stresses up to 80.57 kPa at the distal end of the soft tissue. The longitudinal and circumferential shear stress distributions at the limb-socket interface were also simulated. This study explores the influences of load transfer between trans-femoral residual limb and its prosthetic socket.Keywords
This publication has 17 references indexed in Scilit:
- Finite Element Analysis of Donning Procedure of a Prosthetic Transfemoral SocketAnnals of Biomedical Engineering, 2011
- Patient-specific analyses of deep tissue loads post transtibial amputation in residual limbs of multiple prosthetic usersJournal of Biomechanics, 2009
- Internal mechanical conditions in the soft tissues of a residual limb of a trans-tibial amputeeJournal of Biomechanics, 2008
- Using computational simulation to aid in the prediction of socket fit: A preliminary studyMedical Engineering & Physics, 2006
- Finite element modeling of the contact interface between trans-tibial residual limb and prosthetic socketMedical Engineering & Physics, 2004
- Comparison of computational analysis with clinical measurement of stresses on a below-knee residual limb in a prosthetic socket: [Medical Engineering & Physics 22 (2000):607–12]Medical Engineering & Physics, 2001
- Identification of pressure distribution at the socket interface of an above-knee prosthesisAdvances in Engineering Software, 1997
- Finite element modeling and experimental verification of lower extremity shape change under loadJournal of Biomechanics, 1997
- A finite element analysis of the load transfer between an above-knee residual limb and its prosthetic socket-roles of interface friction and distal-end boundary conditionsIEEE Transactions on Rehabilitation Engineering, 1996
- THE SKIN SURFACE AND FRICTION.British Journal of Dermatology, 1955