Real‐time volumetric image reconstruction and 3D tumor localization based on a single x‐ray projection image for lung cancer radiotherapy
Authors:
- Ruijiang LiRLRuijiang Li
- Xun JiaXJXun Jia
- John H. LewisJLJohn H. Lewis
- Xuejun GuXGXuejun Gu
- Michael FolkertsMFMichael Folkerts
- Chunhua MenCMChunhua Men
- Steve B. JiangSJSteve B. Jiang
- 21 May 2010
- journal article
- Published by Wiley in Medical Physics
- Vol. 37 (6Part1) , 2822-2826
Abstract
Purpose: To develop an algorithm for real‐time volumetric image reconstruction and 3D tumor localization based on a single x‐ray projection image for lung cancer radiotherapy.Methods: Given a set of volumetric images of a patient at breathing phases as the training data, deformable image registration was performed between a reference phase and the other phases, resulting in deformation vector fields (DVFs). These DVFs can be represented efficiently by a few eigenvectors and coefficients obtained from principal component analysis (PCA). By varying the PCA coefficients, new DVFs can be generated, which, when applied on the reference image, lead to new volumetric images. A volumetric image can then be reconstructed from a single projection image by optimizing the PCA coefficients such that its computed projection matches the measured one. The 3D location of the tumor can be derived by applying the inverted DVF on its position in the reference image. The algorithm was implemented on graphics processing units (GPUs) to achieve real‐time efficiency. The training data were generated using a realistic and dynamic mathematical phantom with ten breathing phases. The testing data were 360 cone beam projections corresponding to one gantry rotation, simulated using the same phantom with a 50% increase in breathing amplitude.Results: The average relative image intensity error of the reconstructed volumetric images is . The average 3D tumor localization error is . On an NVIDIA Tesla C1060 GPU card, the average computation time for reconstructing a volumetric image from each projection is 0.24 s (range: 0.17 and 0.35 s).Conclusions: The authors have shown the feasibility of reconstructing volumetric images and localizing tumor positions in 3D in near real‐time from a single x‐ray image.Keywords
All Related Versions
Funding Information
- Varian Master Research Agreement
This publication has 16 references indexed in Scilit:
- The diaphragm as an anatomic surrogate for lung tumor motionPhysics in Medicine & Biology, 2009
- Fluoroscopic tumor tracking for image-guided lung cancer radiotherapyPhysics in Medicine & Biology, 2009
- Gating based on internal/external signals with dynamic correlation updatesPhysics in Medicine & Biology, 2008
- Lung tumor tracking in fluoroscopic video based on optical flowMedical Physics, 2008
- A patient‐specific respiratory model of anatomical motion for radiation treatment planningMedical Physics, 2007
- Multiple template-based fluoroscopic tracking of lung tumor mass without implanted fiducial markersPhysics in Medicine & Biology, 2007
- Estimating 3-D Respiratory Motion From Orbiting Views by Tomographic Image RegistrationIEEE Transactions on Medical Imaging, 2007
- Residual motion of lung tumors in end‐of‐inhale respiratory gated radiotherapy based on external surrogatesMedical Physics, 2006
- The management of respiratory motion in radiation oncology report of AAPM Task Group 76a)Medical Physics, 2006
- Correlation of lung tumor motion with external surrogate indicators of respirationInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2004