Public Health England survey of eye lens doses in the UK medical sector
Authors:
- E A AinsburyEAE A Ainsbury
- S BoufflerSBS Bouffler
- M CockerMCM Cocker
- P GilvinPGP Gilvin
- E HoltEHE Holt
- S PetersSPS Peters
- K SlackKSK Slack
- A WilliamsonAWA Williamson
- 22 November 2013
- journal article
- research article
- Published by IOP Publishing in Journal of Radiological Protection
- Vol. 34 (1) , 15-29
Abstract
The ICRP has recently recommended that the occupational exposure limit for the lens of the eye be reduced to 20 mSv in a year, averaged over defined periods of 5 years, with no single year exceeding 50 mSv. There has been concern amongst some groups of individuals, particularly interventional cardiologists and radiologists as well as relevant professional bodies, that implementation of these recommendations into UK law will adversely affect working patterns. However, despite a number of informative European studies, there is currently little UK dosimetry data available upon which judgements can effectively be based. In order to address this knowledge gap, Public Health England has carried out a small, targeted survey of UK lens doses to medical staff undertaking procedures likely to involve the highest levels of radiation exposure. Two out of a total of 61 individuals surveyed had projected annual doses which could be close to 20 mSv, measured outside lead glasses. Use of protective equipment was generally good; however, lead glasses were only used by 9 participants. The results of this survey suggest that compliance with the ICRP recommendations is likely to be possible for most individuals in the UK medical sector.Keywords
This publication has 21 references indexed in Scilit:
- Type testing of a head band dosemeter for measuring eye lens dose in terms of HP(3)Radiation Protection Dosimetry, 2013
- Radiation-induced cataracts: the Health Protection Agency’s response to the ICRP statement on tissue reactions and recommendation on the dose limit for the eye lensJournal of Radiological Protection, 2012
- Occupational Radiation Dose:Percutaneous Interventional Procedures on Hemodialysis Arteriovenous Fistulas and GraftsRadiology, 2012
- Radiation exposure in interventional proceduresRadiation Protection Dosimetry, 2012
- Staff eye lens and extremity exposure in interventional cardiology: Results of the ORAMED projectRadiation Measurements, 2011
- Is the new ICRP eye dose limit justified? Comment on 'A German storm affecting Britain: childhood leukaemia and nuclear power plants' Reply to Comment on 'A German storm affecting Britain: childhood leukaemia and nuclear power plants' Comment on 'A German storm affecting Britain: childhood leukaemia and nuclear power plants' Reply to Comment on 'A German storm affecting Britain: childhood leukaemia and nuclear power plants' Compact fluorescent lightsJournal of Radiological Protection, 2011
- A 20 mSv dose limit for the eye: sense or no sense?Journal of Radiological Protection, 2011
- Occupational radiation doses to the extremities and the eyes in interventional radiology and cardiology proceduresBritish Journal of Radiology, 2011
- Extremity and eye lens doses in interventional radiology and cardiology procedures: first results of the ORAMED projectRadiation Protection Dosimetry, 2010
- Radiation Cataractogenesis: A Review of Recent StudiesRadiation Research, 2009