Rapid construction of a patient-specific torso model from 3D ultrasound for non-invasive imaging of cardiac electrophysiology
- 1 June 2005
- journal article
- research article
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 43 (3) , 325-330
Abstract
One of the main limitations in using inverse methods for non-invasively imaging cardiac electrical activity in a clinical setting is the difficulty in readily obtaining high-quality data sets to reconstruct accurately a patient-specific geometric model of the heart and torso. This issue was addressed by investigation into the feasibility of using a pseudo-3D ultrasound system and a hand-held laser scanner to reconstruct such a model. This information was collected in under 20 min prior to a catheter ablation or pacemaker study in the electrophysiology laboratory. Using the models created from these data, different activation field maps were computed using several different inverse methods. These were independently validated by comparison of the earliest site of activation with the physical location of the pacing electrodes, as determined from orthogonal fluoroscopy images. With an estimated average geometric error of approximately 8 mm, it was also possible to reconstruct the site of initial activation to within 17.3 mm and obtain a quantitatively realistic activation sequence. The study demonstrates that it is possible rapidly to construct a geometric model that can then be used non-invasively to reconstruct an activation field map of the heart.Keywords
This publication has 21 references indexed in Scilit:
- A Comparison of Noninvasive Reconstruction of Epicardial Versus Transmembrane Potentials in Consideration of the Null SpaceIEEE Transactions on Biomedical Engineering, 2004
- Heart-surface reconstruction and ecg electrodes localization using fluoroscopy, epipolar geometry and stereovision: application to noninvasive imaging of cardiac electrical activityIEEE Transactions on Medical Imaging, 2003
- Effects of experimental and modeling errors on electrocardiographic inverse formulationsIEEE Transactions on Biomedical Engineering, 2003
- Comparison of potential- and activation-based formulations for the inverse problem of electrocardiologyIEEE Transactions on Biomedical Engineering, 2003
- Noninvasive myocardial activation time imaging: a novel inverse algorithm applied to clinical ECG mapping dataIEEE Transactions on Biomedical Engineering, 2002
- Creation of a Human Heart, Model and its Customisation using Ultrasound ImagesBiomedical Engineering / Biomedizinische Technik, 2001
- System for quantitative three-dimensional echocardiography of the left ventricle based on a magnetic-field position and orientation sensing systemIEEE Transactions on Biomedical Engineering, 1998
- Noninvasive Electrocardiographic ImagingCirculation, 1997
- Localization of the site of origin of postinfarction ventricular tachycardia by endocardial pace mapping. Body surface mapping compared with the 12-lead electrocardiogram.Circulation, 1993
- A simple, indifferent, electrocardiographic electrode of zero potential and a technique of obtaining augmented, unipolar, extremity leadsAmerican Heart Journal, 1942