Remote Supervision to Decrease Hospitalization Rate (RESULT) study in patients with implanted cardioverter-defibrillator
Authors:
- 18 April 2020
- journal article
- research article
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 22 (5) , 769-776
Abstract
Aims: The number of patients with heart failure (HF) and implantable cardiac electronic devices has been growing steadily. Remote monitoring care (RC) of cardiac implantable electronic devices can facilitate patient-healthcare clinical interactions and prompt preventive activities to improve HF outcomes. However, studies that have investigated the efficacy of remote monitoring have shown mixed findings, with better results for the system including daily verification of transmission. The purpose of the RESULT study was to analyse the impact of remote monitoring on clinical outcomes in HF patients with implantable cardioverter-defibrillator [ICD/cardiac resynchronization therapy-defibrillator (CRT-D)] in real-life conditions. Methods and results: The RESULT is a prospective, single-centre, randomized trial. Patients with HF and de novo ICD or CRT-D implantation were randomized to undergo RC vs. in-office follow-ups (SC, standard care). The primary endpoint was a composite of all-cause death and hospitalization due to cardiovascular reasons within 12 months after randomization. We randomly assigned 600 eligible patients (299 in RC vs. 301 in SC). Baseline clinical and echocardiographic characteristics were well-balanced and similar in both arms. The incidence of the primary endpoint differed significantly between RC and SC and involved 39.5% and 48.5% of patients, respectively, (P = 0.048) within the 12-month follow-up. The rate of all-cause mortality was similar between the studied groups (6% vs. 6%, P = 0.9), whereas hospitalization rate due to cardiovascular reasons was higher in SC (37.1% vs. 45.5%, P = 0.045). Conclusion: Remote monitoring of HF patients with implanted ICD or CRT-D significantly reduced the primary endpoint rate, mostly as a result of a lower hospitalization rate in the RC arm (ClinicalTrials.gov Identifier: NCT02409225).Keywords
Funding Information
- National Centre for Research and Development (STRATEGMED1/233221/3/NCBR/2014)
This publication has 20 references indexed in Scilit:
- Remote management of heart failure using implantable electronic devicesEuropean Heart Journal, 2017
- Daily remote monitoring of implantable cardioverter-defibrillators: insights from the pooled patient-level data from three randomized controlled trials (IN-TIME, ECOST, TRUST)European Heart Journal, 2017
- Impact of Remote Monitoring on Long‐Term Prognosis in Heart Failure Patients in a Real‐World Cohort: Results From All‐Comers COMMIT‐HF TrialJournal of Cardiovascular Electrophysiology, 2017
- Effects of Remote Monitoring on Clinical Outcomes and use of Healthcare Resources in Heart Failure Patients with Biventricular Defibrillators: Results of the More-Care Multicentre Randomized Controlled TrialEuropean Journal of Heart Failure, 2016
- 2016 ESC Guidelines for the diagnosis and treatment of acute and chronic heart failureEuropean Heart Journal, 2016
- HRS Expert Consensus Statement on remote interrogation and monitoring for cardiovascular implantable electronic devicesHeart Rhythm, 2015
- Remote Monitoring of Implantable Cardioverter-DefibrillatorsJACC, 2015
- Remote monitoring improves outcome after ICD implantation: the clinical efficacy in the management of heart failure (EFFECT) studyEP Europace, 2015
- Implant-based multiparameter telemonitoring of patients with heart failure (IN-TIME): a randomised controlled trialThe Lancet, 2014
- EUR Observational Research Programme: regional differences and 1-year follow-up results of the Heart Failure Pilot Survey (ESC-HF Pilot)European Journal of Heart Failure, 2013